DTC No.
| Monitoring Item
| Malfunction Detection Condition
| Trouble Area
| Detection Timing
| Detection Logic
|
P2401
| Leak detection pump stuck OFF
| Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine leak criterion. Reference leak pressure standard is measured at the start and at the end of the leak check. If system pressure higher than -1.06 kPa (-7.93 mmHg)*, or lower than -4.85 kPa (-36.38 mmHg)*, ECM determines that leak detection pump stuck OFF.
| - Canister pump module (reference orifice, leak detection pump, vent valve)
- Connector/wire harness (canister pump module - ECM)
- ECM
| Ignition switch OFF
| 2 trip
|
P2402
| Leak detection pump stuck ON
| Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine leak criterion. If system pressure higher than -1.06 kPa (-7.93 mmHg)*, or lower than -4.85 kPa (-36.38 mmHg)*, ECM determines that leak detection pump stuck ON.
| - Canister pump module (reference orifice, leak detection pump, vent valve)
- Connector/wire harness (canister pump module - ECM)
- ECM
| Ignition switch OFF
| 2 trip
|
Sequence
| Operation
| Description
| Duration
|
-
| ECM activation
| Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF.
| -
|
A
| Atmospheric pressure measurement
| Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
| 10 seconds
|
B
| First 0.02 inch leak criterion (reference pressure) measurement
| In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
| 60 seconds
|
C
| EVAP system pressure measurement
| Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 900 seconds, ECM cancels EVAP system monitor.
| 900 seconds*
|
D
| Purge VSV monitor
| Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal.
| 10 seconds
|
E
| Second 0.02 inch leak criterion (reference pressure) measurement
| After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
| 60 seconds
|
F
| Final check
| Atmospheric pressure measured and then monitoring result recorded by ECM.
| -
|
The monitor will run whenever these DTCs are not present
| None
|
Atmospheric pressure
| 70 to 110 kPa (525 to 825 mmHg)
|
Battery voltage
| 10.5 V or higher
|
Vehicle speed
| 2.5 mph (4 km/h) or less
|
Ignition switch
| OFF
|
Time after key off
| 5 or 7 or 9.5 hours
|
EVAP pressure sensor malfunction (P0450, P0452, P0453)
| Not detected
|
EVAP canister purge valve
| Not operated by scan tool
|
EVAP canister vent valve
| Not operated by scan tool
|
EVAP leak detection pump
| Not operated by scan tool
|
Both of the following conditions are met before key off
| Condition 1 and 2
|
1. Duration that vehicle has been driven
| 5 minutes or more
|
2. EVAP purge operation
| Performed
|
ECT
| 4.4 to 35°C (40 to 95°F)
|
IAT
| 4.4 to 35°C (40 to 95°F)
|
One of the following conditions set
| Condition 1, 2, 3, 4 or 5
|
1. EVAP pressure just after reference pressure measurement start
| -1 kPa (7.5 mmHg) or higher
|
2. Reference pressure
| Less than -4.85 kPa (726 mmHg)
|
3. Reference pressure
| -1.05 kPa (754 mmHg) or higher
|
4. Reference pressure
| Not saturated
|
5. Difference between first reference pressure and second reference pressure
| 0.7 kPa (5.25 mmHg) or more
|