Home › ENGINE ยท 2UZ-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P2419    Evaporative Emission Pressure Switching Valve Stuck ON

DTC    P2420    Evaporative Emission Pressure Switching Valve Stuck OFF

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Items
Malfunction Detection Conditions
Trouble Areas
Detection Timing
Detection Logic
P2419
Vent valve stuck closed
Vacuum pump creates negative pressure through 0.02 inch orifice and EVAP system pressure measured to determine leak pressure standard.
If system pressure higher than -1.06 kPa (-7.95 mmHg)* 4 seconds after vacuum pump turned ON, ECM determines that vent valve stuck closed.
  1. Pump module
  2. Connector / Wire harness (Pump module - ECM)
  3. ECM
Ignition switch OFF
2 trip
P2420
Vent valve stuck open (vent)
Vacuum pump creates negative pressure through 0.02 inch orifice and EVAP system pressure measured to determine leak pressure standard. 0.02 inch leak pressure standard is measured at the start and at the end of the leak check.
If system pressure does not increase by more than 0.3 kPa (2.25 mmHg) within 10 seconds when vent valve turned ON, ECM determines that vent valve stuck closed.
  1. Pump module
  2. Connector / Wire harness (Pump module - ECM)
  3. ECM
Ignition switch OFF
2 trip
*: The threshold valve varies according to the atmospheric presser measured in operation A. The value described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.

HINT:
The vent value is built into the pump module.


DESCRIPTION

The circuit description can be found in the Evaporative Emission (EVAP) system .

INSPECTION PROCEDURE

Refer to the EVAP system .

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned OFF, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned OFF, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned OFF, the monitor check starts 2.5 hours later.


Sequence
Operations
Descriptions
Duration
-
ECM activation
Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak criterion (reference pressure) measurement
In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 900 seconds, ECM cancels EVAP system monitor.
900 seconds*
D
Purge VSV monitor
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak criterion (reference pressure) measurement
After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion.
If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
60 seconds
F
Final check
Atmospheric pressure measured and then monitoring result recorded by ECM.
-
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E05


  1. P2419: Vent valve stuck closed
    In operation B, the leak detection pump creates negative pressure (vacuum) through the reference orifice. The EVAP system pressure is then measured by the ECM using the canister pressure sensor to determine the 0.02 inch leak criterion. If the pressure exceeds -1.06 kPa (-7.95 mmHg)* 4 seconds after the leak detection pump is turned ON, the ECM interprets this as the vent valve being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).
    *: The threshold varies according to the atmospheric pressure measured in operation A. The values described above is based on an atmospheric pressure of 100 kPa (750.1 mmHg): absolute pressure.


    A106066E03


  2. P2420: Vent valve stuck open (vent)
    In operation C, the vent valve turns ON (closes) and the EVAP system pressure is then measured by the ECM using the canister pressure sensor to conduct an EVAP leak check. If pressure does not drop when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and sets the DTC.


    A106067E03


MONITOR STRATEGY


Required Sensors/Components
Purge VSV and canister pump module
Frequency of Operation
Once per driving cycle
Duration
2 minutes
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever these DTCs are not present
None
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or higher
Vehicle speed
2.5 mph (4 km/h) or less
Ignition switch
OFF
Time after key off
5 or 7 or 9.5 hours
EVAP pressure sensor malfunction (P0450, P0452, P0453)
Not detected
EVAP canister purge valve
Not operated by scan tool
EVAP canister vent valve
Not operated by scan tool
EVAP leak detection pump
Not operated by scan tool
Both of the following are met before key off
Condition 1 and 2
1. Duration that vehicle has been driven
5 minutes or more
2. EVAP purge operation
Performed
ECT
4.4 to 35°C (40 to 95°F)
IAT
4.4 to 35°C (40 to 95°F)

Key-off monitor sequence 1 to 8

1. Atmospheric pressure measurement 
Next sequence is run if the following condition is met
-
Atmospheric pressure change
Within 0.3 kPa (2.25 mmHg) in 1 second

2. First reference pressure measurement 
Next sequence is run if the following conditions set
-
EVAP pressure just after reference pressure measurement start
-1 kPa (-7.5 mmHg) or lower
Reference pressure
-4.85 to -1.05 kPa (726 to 754 mmHg)
Reference pressure
Saturated

3. Vent valve stuck closed check 
Next sequence is run if the following conditions set
-
EVAP pressure change after vent valve is ON
0.3 kPa (2.25 mmHg) or more

4. Vacuum introduction 
Next sequence is run if the following conditions set
-
EVAP pressure
Saturated within 900 seconds

5. Purge VSV stuck closed check 
Next sequence is run if the following conditions set
-
EVAP pressure change after purge valve is open
0.3 kPa (2.25 mmHg) or more

6. Second reference pressure measurement 
Next sequence is run if the following conditions set
-
EVAP pressure just after reference pressure measurement
-1 kPa (-7.5 mmHg) or lower
Reference pressure
-4.85 to -1.05 kPa (-36.38 to -7.93 mmHg)
Reference pressure
Saturated within 55 seconds
Difference between first reference pressure and second reference pressure
Less than 0.7 kPa (5.25 mmHg)

7. Leak check 
Next sequence is run if the following conditions set
-
EVAP pressure when vacuum introduction is complete
Lower than second reference pressure

8. Atmospheric pressure measurement 
EVAP monitor is complete if the following conditions set
-
Atmospheric pressure difference between sequence 1 and 8
Within 0.3 kPa (2.25 mmHg)

TYPICAL MALFUNCTION THRESHOLDS

  1. P2419: Vent valve stuck closed
    "Saturated" indicates that the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) in 30 seconds.

    One of following conditions set
    -
    1. EVAP pressure just after reference pressure measurement start
    -1 kPa (-7.5 mmHg) or higher
    2. Reference pressure
    Less than -4.85 kPa (726 mmHg)
    3. Reference pressure
    -1.05 kPa (-7.93 mmHg) or higher
    4. Reference pressure
    Not saturated
    5. Difference between first reference pressure and second reference pressure
    0.7 kPa (5.25 mmHg) or more
  2. P2420: Vent valve stuck open (vent)

    EVAP pressure change after EVAP canister vent valve is ON
    Less than 0.286 kPa (2.25 mmHg)

MONITOR RESULT

Refer to detailed information on Checking Monitor Status (Click here).