DTC B1150/23 Occupant Classification System Malfunction |
| DTC No. | DTC Detecting Condition | Trouble Area |
| B1150/23 |
|
|

| 1.CHECK DTC (OCCUPANT CLASSIFICATION ECU) |
Turn the ignition switch to the ON position, and wait for at least 10 seconds.
Using the intelligent tester, check the DTCs of the occupant classification ECU (Click here).
|
| ||||
| OK | |
| 2.CHECK DTC (CENTER AIRBAG SENSOR ASSEMBLY) |
![]() |
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 3.CHECK CONNECTION OF CONNECTORS |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor assembly and the occupant classification ECU.
|
| ||||
| OK | |
| 4.CHECK OCCUPANT CLASSIFICATION ECU CIRCUIT (SHORT TO GROUND) |
![]() |
Disconnect the connectors from the center airbag sensor assembly and the occupant classification ECU.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| O3-8 (FSR+) - Body ground | Always | 1 MΩ or higher |
| O3-4 (FSR-) - Body ground | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 5.CHECK OCCUPANT CLASSIFICATION ECU CIRCUIT (SHORT TO B+) |
![]() |
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| O3-8 (FSR+) - Body ground | Ignition switch ON | Below 1 V |
| O3-4 (FSR-) - Body ground | Ignition switch ON | Below 1 V |
|
| ||||
| OK | |
| 6.CHECK OCCUPANT CLASSIFICATION ECU CIRCUIT (SHORT) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| O3-8 (FSR+) - O3-4 (FSR-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 7.CHECK OCCUPANT CLASSIFICATION ECU CIRCUIT (OPEN) |
![]() |
with Side and curtain shield airbag:
Using a service wire, connect A33-1 (FSR+) and A33-2 (FSR-) of connector "B".
without Side and curtain shield airbag:
Using a service wire, connect A34-3 (FSR+) and A34-10 (FSR-) of connector "B".
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| O3-8 (FSR+) - O3-4 (FSR-) | Always | Below 1 Ω |
|
| ||||
| OK | |
| 8.CHECK FLOOR WIRE (SHORT TO GROUND) |
![]() |
Disconnect the floor wire connector from the seat wire No. 1.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| Bl1-1 (FSR+) - Body ground | Always | 1 MΩ or higher |
| Bl1-4 (FSR-) - Body ground | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 9.CHECK FLOOR WIRE (SHORT TO B+) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the floor wire connector from the seat wire No. 1.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| Bl1-1 (FSR+) - Body ground | Ignition switch ON | Below 1 V |
| Bl1-4 (FSR-) - Body ground | Ignition switch ON | Below 1 V |
|
| ||||
| OK | ||
| ||
| 10.CHECK FLOOR WIRE (SHORT) |
![]() |
Disconnect the floor wire connector from the seat wire No. 1.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| Bl1-1 (FSR+) -Bl1-4 (FSR-) | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 11.CHECK FLOOR WIRE (OPEN) |
![]() |
Disconnect the floor wire connector from the seat wire No. 1.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| Bl1-1 (FSR+) - Bl1-4 (FSR-) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||