Home › BRAKE › BRAKE CONTROL › VEHICLE STABILITY CONTROL SYSTEM

VEHICLE STABILITY CONTROL SYSTEM > ABS Warning Light Remains ON

for Preparation Click here


DESCRIPTION

If any of the following is detected, the ABS warning light remains on.
  1. The skid control ECU connectors are disconnected from the skid control ECU.
  2. There is a malfunction in the skid control ECU internal circuit.
  3. There is an open in the harness between the combination meter and skid control ECU.

HINT:
There is a case that the intelligent tester cannot be used when the skid control ECU is abnormal.


WIRING DIAGRAM


C132925E01


INSPECTION PROCEDURE

NOTICE:
When replacing the master cylinder solenoid, perform zero point calibration (Click here).

1.INSPECT IF SKID CONTROL ECU CONNECTOR IS SECURELY CONNECTED
  1. Check the skid control ECU connector's connecting condition.

OK:
The connector should be securely connected.



NG
CONNECT CONNECTOR TO ECU
OK


2.INSPECT BATTERY
  1. Check the battery voltage.

    Standard voltage:
    11 to 14 V



NG
INSPECT CHARGING SYSTEM
OK


3.INSPECT SKID CONTROL ECU (IG1 TERMINAL)


    C121700E89
  1. Disconnect the skid control ECU connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    S28-46 (IG1) -Body ground
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (IG1 CIRCUIT)
OK


4.INSPECT SKID CONTROL ECU (GND TERMINAL)


    C124799E17
  1. Disconnect the skid control ECU (S29) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    S28-1 (GND1) - Body ground
    Below 1 Ω
    S28-32 (GND2) - Body ground
    Below 1 Ω
    S29-4 (GND3) - Body ground
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (GND CIRCUIT)
OK


5.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)


    I045766E03
  1. Disconnect the combination meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    S28-29 (WA) - C11-4
    Below 1 Ω
    S28-29 (WA) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.INSPECT COMBINATION METER ASSEMBLY
  1. Check the combination meter system (Click here).



NG
REPLACE COMBINATION METER ASSEMBLY
OK

REPLACE MASTER CYLINDER SOLENOID