DTC P0441 Evaporative Emission Control System Incorrect Purge Flow |
| DTCs | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timings | Detection Logic |
| P0441 | Purge VSV (Vacuum Switching Valve) stuck open | Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. The 0.02 inch leak pressure standard is measured at the start and end of the leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM determines that purge VSV is stuck open |
| While ignition Switch OFF | 2 trip |
| P0441 | Purge VSV stuck closed | After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air is introduced into EVAP system. 0.02 inch leak pressure standard is measured at the start and end of leak check. If pressure does not return to near atmospheric pressure, ECM determines that purge valve is stuck closed |
| While ignition Switch OFF | 2 trip |
| P0441 | Purge flow | While engine running, the following conditions successively met:
|
| While engine running | 2 trip |
| KEY-OFF MONITOR |
| Sequence | Operations | Descriptions | Duration |
| - | ECM activation | Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak pressure measurement | In order to determine 0.02 inch leak pressure standard, vacuum pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM checks if vacuum pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in the leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. | 15 minutes*2
|
| D | Purge VSV monitor | Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak pressure measurement | After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards. If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM determines that EVAP system leaking. | 60 seconds |
| F | Final check | Atmospheric pressure is measured and then monitoring result is recorded by ECM. | - |

Purge VSV stuck open
In operation C, the vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM using the pressure sensor. If the stabilized system pressure is higher than [second 0.02 inch leak pressure standard x 0.2], the ECM interprets this as the purge VSV (Vacuum Switching Valve) being stuck open. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

Purge VSV stuck closed
In operation D, the pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for purge VSV monitor is begun when the purge VSV is turned on (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa (2.25 mmHg) or more, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

| PURGE FLOW MONITOR |
![]() |
| Related DTCs | P0441: Purge VSV stuck open P0441: Purge VSV stuck closed P0441: Purge flow |
| Required Sensors / Components | Purge VSV and pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Purge VSV stuck open and closed: Within 15 minutes. (varies with amount of fuel in tank) Purge flow: Within 10 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| The monitor is run whenever this DTC is not present | P0011, P0012 (VVT System-Advance, Retard), P0021, P0022 (VVT System2-Adavance, Retard), P0100, P0101, P0102, P0103 (MAF Sensor), P0110, P0112, P0113 (IAT Sensor),P0115, P0116, P0117, P0118 (ECT Sensor), P0120, P0121, P0122, P0123, P0220, P0222, P0223 , P2135 (TP Sensor), P0125 (Insufficient ECT for Closed Loop), P0171,P0172 (Fuel System), P0300, P0301, P0302, P0303, P0304, P0305, P0306 (Misfire), P0335 (CKP Sensor), P0340 (CMP sensor), P0342, P0343, P0345 (VVT Sensor 1, 2), P0351, P0352, P0353, P0354, P0355, P0356 (Ignitor), P0450, P0451, P0452, P0453 (EVAP pressure Sensor), P0500 (VSS) |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Less than 2.5 mph (4 km/h) |
| Ignition switch | OFF |
| Time after key-off | 5 or 7 or 9.5 hours |
| EVAP pressure sensor malfunction (P0450, P0452, P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before key off | Condition 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
| Next sequence is run if the following condition is set | - |
| Atmospheric pressure change | Less than 0.3 kPa (2.25 mmHg) in 1 second |
| Next sequence is run if the following conditions are set | Condition 1, 2 and 3 |
| 1. EVAP pressure just after reference pressure measurement start | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.38 to -7.93 mmHg) |
| 3. Reference pressure | Saturated |
| Next sequence is run if the following condition is set | - |
| EVAP pressure change after vent valve is ON | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following condition is set | - |
| EVAP pressure | Saturated within 12 minutes |
| Next sequence is run if the following condition is met | - |
| EVAP pressure change after purge valve is open | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following conditions are met | Condition 1, 2, 3 and 4 |
| 1. EVAP pressure just after reference pressure | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.384 to -7.929 mmHg) |
| 3. Reference pressure | Saturated |
| 4. Difference between first reference pressure and second reference pressure | Less than 0.7 kPa (5.25 mmHg) |
| Next sequence is run if the following condition is met | - |
| EVAP pressure when vacuum introduction is complete | Lower than second reference pressure |
| EVAP monitor is complete if the following condition is met | - |
| Atmospheric pressure difference between sequence 1 and 8 | Within 0.3 kPa (2.25 mmHg) |
| Engine | Running |
| ECT | 4.4°C (40°F) or more |
| IAT | 4.4°C (40°F) or more |
| EVAP pressure sensor | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP system check | Not operated by scan tool |
| Battery voltage | 10 V or more |
| Purge duty cycle | 8% or more |
| Both of the following conditions are met | Condition (a) and (b) |
| (a) EVAP pressure change when purge flow is started | Less than 0.1 kPa (0.75 mmHg) |
| (b) EVAP pressure change during purge flow when EVAP pressure switching valve ON (closed) | Less than 0.5 kPa (3.75 mmHg) |
| EVAP pressure when vacuum introduction is complete | Higher than reference pressure x 0.2 |
| EVAP pressure change after EVAP canister purge valve is open | Less than 0.3 kPa (2.25 mmHg) |