DTC P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) |
DTC P0032 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1) |
DTC P0051 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1) |
DTC P0052 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1) |

| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0031 P0051 | Air-Fuel Ratio (A/F) sensor heater current less than 0.8 A (1 trip detection logic) |
|
| P0032 P0052 | Air-Fuel Ratio (A/F) sensor heater current more than 10 A (1 trip detection logic) |
|
| Related DTCs | P0031: A/F sensor heater (Bank 1) range check (Low current) P0032: A/F sensor heater (Bank 1) range check (High current) P0051: A/F sensor heater (Bank 2) range check (Low current) P0052: A/F sensor heater (Bank 2) range check (High current) |
| Required sensors / components (Main) | A/F sensor heater |
| Required sensors / components (Related) | - |
| Frequency of operation | Continuous |
| Duration | 10 seconds |
| MIL operation | Immediate |
| Sequence operation | None |
| The monitor will run whenever these DTCs are not present | None |
| Battery voltage | 10.5 V or more |
| A/F sensor heater duty ratio | 50% or more |
| Time after engine start | 10 seconds or more |
| Time after engine start | 10 seconds or more |
| A/F sensor heater current | Less than 0.8 A |
| A/F sensor heater current | More than 10 A |
| A/F sensor heater current | 1.8 to 3.4 A at 20°C (68°F) |
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
| 1 | $01 | Multiply by 0.00017 (A) | Maximum heater current (Bank 1) | Malfunction criterion for A/F sensor heater |
| 1 | $10 | Multiply by 0.00017 (A) | Maximum heater current (Bank 2) | Malfunction criterion for A/F sensor heater |
| 1.INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE) |
![]() |
Disconnect the A12 or A13 A/F sensor connector.
Measure the resistance between the terminals of the A/F sensor connector.
| Tester Connections | Specified Conditions |
| HT (1) - +B (2) | 1.8 to 3.4 Ω at 20°C (68°F) |
| HT (1) - AF- (4) | 10 kΩ or higher |
Reconnect the A/F sensor connector.
|
| ||||
| OK | |
| 2.INSPECT AIR FUEL RATIO SENSOR RELAY |
![]() |
Remove the A/F sensor heater relay from the engine room R/B.
Measure the A/F sensor heater relay resistance.
| Tester Connections | Specified Conditions |
| 3 - 5 | 10 kΩ or higher |
| 3 - 5 | Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
Reinstall the A/F sensor heater relay.
|
| ||||
| OK | |
| 3.INSPECT ECM (HA1A OR HA2A VOLTAGE) |
![]() |
Turn the ignition switch on (IG).
Measure the voltage between the terminals of the E5 ECM connector.
| Tester Connections | Specified Conditions |
| HA1A (E5-2) - E04 (E5-7) | 9 to 14 V |
| HA2A (E5-1) - E05 (E5-6) | 9 to 14 V |
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (A/F SENSOR - ECM, A/F SENSOR - A/F SENSOR HEATER RELAY) |
![]() |
Check the harness and the connector between the ECM and the A/F sensor.
Disconnect the A12 or A13 A/F sensor connector.
Disconnect the E5 ECM connector.
Measure the resistance.
| Tester Connections | Specified Conditions |
| HT (A12-1) - HA1A (E5-2) | Below 1 Ω |
| HT (A13-1) - HA2A (E5-1) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| HT (A12-1) or HA1A (E5-2) - Body ground | 10 kΩ or higher |
| HT (A13-1) or HA2A (E5-1) - Body ground | 10 kΩ or higher |
Check the harness and the connector between the A/F sensor and engine room junction block (A/F sensor heater relay).
Remove the engine room junction block.
Measure the resistance.
| Tester Connections | Specified Conditions |
| +B (A12-2) -A/F sensor heater relay (3) | Below 1 Ω |
| +B (A13-2) -A/F sensor heater relay (3) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| +B (A12-2) or A/F sensor heater relay (3) - Body ground | 10 kΩ or higher |
| +B (A13-2) or A/F sensor heater relay (3) - Body ground | 10 kΩ or higher |
Reconnect the A/F sensor connector.
Reconnect the ECM connector.
Reinstall the A/F sensor heater relay.
|
| ||||
| OK | ||
| ||