DTC P0604 Internal Control Module Random Access Memory (RAM) Error |
DTC P0606 ECM / PCM Processor |
DTC P0607 Control Module Performance |
DTC P0657 Actuator Supply Voltage Circuit / Open |
| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0604 P0606 P0607 P0657 | ECM internal error (1 trip detection logic) | ECM |
| Related DTCs | P0604: ECM RAM error P0606: ECM range check P0607: ECM CPU malfunction P0657: ETCS power supply |
| Required Sensors / Components (Main) | ECM |
| Required Sensors / Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | Within 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| The monitor will run whenever these DTCs are not present | None |
| RAM | RAM mirror check failure |
| Either of following conditions is met: | Condition 1 or 2 |
| 1. Difference between throttle valve position of main CPU and throttle valve position of sub CPU | 0.3 V or more |
| 2. Difference between accelerator pedal position of main CPU and accelerator pedal position of sub CPU | 0.3 V or more |
| Either of the following conditions is met | Condition 1 or 2 |
| 1. All of following conditions are met | Condition (a), (b) and (c) |
| (a). CPU reset | 1 time or more |
| (b). Difference between TP and APP learned | 0.4 V or more |
| (c). Electronic throttle actuator | OFF |
| 2. CPU reset | 2 times or more |
| ETCS power supply when ignition switch OFF to ON | 7 V or more |
| 1.REPLACE ECM |
Replace the ECM (Click here).
| NEXT | ||
| ||