Home › BODY › SLIDING ROOF › SLIDING ROOF HOUSING

SLIDING ROOF HOUSING > INSPECTION

for Preparation Click here



1. INSPECT SLIDING ROOF MOTOR SWITCH ASSEMBLY


    B064673
  1. Remove the sliding roof motor switch (Click here).

  1. Check the continuity between the terminals when operating the switch.

    Standard resistance:
    Terminals No.
    Switch Operation
    Specified Condition
    1 - 3
    TILT UP is pressed
    Below 1 Ω
    2 - 3
    SLIDE OPEN is pressed
    Below 1 Ω
    1, 2 - 3
    OFF
    10 kΩ or higher

    If the result is not as specified, replace the switch.



2. INSPECT HARNESS AND CONNECTOR (FOR SLIDING ROOF MOTOR ASSEMBLY)


    B059681
  1. Disconnect the sliding roof motor connector (Click here).

  1. Check the connector terminals of the wire harness side connector.

    Standard:
    Terminals No.
    Condition
    Specified Condition
    8 - Body ground
    Constant
    Below 1 Ω
    9 - 8
    Ignition switch ON
    10 to 14 V
    10 - 8
    Constant
    10 to 14 V
    1 - 8
    Constant
    Below 1 Ω
    7 - 8
    TILT UP is pressed
    Below 1 Ω
    6 - 8
    SLIDE OPEN is pressed
    Below 1 Ω

    If the result is not as specified, there may be a malfunction on the wire harness side.