SYSTEM CONTROL
The air conditioning system uses the following types of control.
| Control | Outline | Air Conditioning Type | |
|---|---|---|---|
| Manual | Automatic | ||
| Neural Network Control | This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain. | - | ○ |
| Manual Control | The air conditioning amplifier controls the damper positions (air inlet control damper, air mix control damper and mode control damper) and blower speed in accordance with the positions of the switches (temperature control dial, blower dial, mode select dial and air inlet control switch). | ○ | - |
| Outlet Air Temperature Control | Based on the temperature set at the temperature control switch, the neural network control calculates the outlet air temperature based on the input signals from various sensors. | - | ○ |
| Left and Right Independent Control | The temperature setting for the driver and front passenger is controlled independently in order to provide a separate vehicle interior temperature for the right and left side of the vehicle. Thus, air conditioning control that accommodates occupant preferences has been realized. | - | ○ |
| Blower Control | Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors. | - | ○ |
| Air Outlet Control | Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control based on the input signals from various sensors. | - | ○ |
| In accordance with the engine coolant temperature, ambient air temperature, amount of sunlight, required blower, outlet temperature, and vehicle speed conditions, this control automatically switches the blower outlet to foot and defroster mode to prevent the windows from becoming fogged up when the ambient air temperature is low. | - | ○ | |
| Air Inlet Control | Automatically controls the air inlet control damper to achieve the calculated outlet air temperature that is required. | - | ○ |
| Drives the air inlet control servo motor according to the operation of the air inlet control switch and moves the dampers to the fresh or recirculation position. | ○ | ○ | |
| Automatically moves the damper to the recirculation position to cool the cabin quickly when the air conditioning is auto mode. | - | ○ | |
| Compressor Control | Controls the compressor assembly to turn on or off based on the signals from various sensors. | ○ | ○ |
| MAX Air Conditioning Control | When the temperature control dial is turned to the MAX A/C position, the air conditioning amplifier performs the following control to improve cooling efficiency:
·
Turns the air conditioning compressor on. ·
Activates the servomotor (air inlet) to set the air inlet control damper to the recirculation position.* |
○ | - |
| Rear Defogger Control | When the ignition switch is on and the rear defogger switch is pushed, the system is activated to keep the rear defogger and outside rear view mirror heaters on for approximately. 15 minutes. However, the operating time of the rear defogger can be extended up to approximately. 255 minutes when the following requirements are met:
·
Ambient Temperature: 0°C or less ·
Vehicle Speed: 31.1 mph (50 km/h) or more |
○ | ○ |
| Front Wiper Deicer Control | Switches the front wiper deicer on for approx. 15 minutes when the front wiper deicer switch is pressed. | ○ | ○ |
| Diagnosis | A Diagnostic Trouble Code (DTC) is stored in the memory when the air conditioning amplifier detects a problem with the air conditioning system. | ○ | ○ |
○: Equipped
-: Not equipped
*: Only when defroster mode is not selected
Neural Network Control
Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier. The air conditioning amplifier can then effect control to provide enhanced air conditioning comfort.
The neural network control consists of neurons in the input layer, intermediate layer, and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, the air conditioning amplifier controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.
CONSTRUCTION
Air Conditioning Control Panel
An electric type heater control assembly that has push switches and control dials is used.
The automatic air conditioning status is displayed on an LCD (Liquid Crystal Display) panel.
On models with automatic air conditioning, as part of the right/left independent temperature control, the temperature control dials for the driver and the front passenger have been located closer to their respective seats for enhanced ease of use.
On models with manual air conditioning, the MAX A/C setting is provided on the temperature control dial to improve cooling efficiency.
Air Conditioning Unit
The air conditioning unit consists of the evaporator, heater radiator unit sub-assembly, servo motors, evaporator temperature sensor (cooler thermistor) and blower with fan motor sub-assembly.
The evaporator and heater radiator unit sub-assembly are mounted transversely to achieve a compact and lightweight form.
A bus connector is used in the wire harness connection that connects the servo motor to the air conditioning amplifier.
| *1 | Evaporator | *2 | Heater Radiator Sub-assembly |
| *a | Side View | *b | Top View |
|
Front | - | - |
A partial recirculation system is used. This system has an air inlet control door (sub) in the cabin side of the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus enhancing heating performance. When the blower switch is on, the suction force of the blower fan opens this air inlet control door (sub).
Evaporator
Placing the tanks at the top and the bottom of the evaporator and adopting a micropore tube construction has provided the following benefits:
Improved heat exchange efficiency
More uniform temperature distribution
A thinner evaporator
| *1 | Tank | *2 | Cooling Fin |
| *3 | Micropore Tube | - | - |
Evaporator Temperature Sensor (Cooler Thermistor)
The evaporator temperature sensor (cooler thermistor) detects the temperature of the cooled air immediately past the evaporator in the form of resistance changes, and outputs this data to the air conditioning amplifier.
Heater Radiator Unit Sub-assembly
The compact, lightweight and highly efficient Straight Flow Aluminum (SFA)-II type heater radiator unit sub-assembly is used for the air conditioning system.
| *1 | Tank | - | - |
Blower with Fan Motor Sub-assembly
The blower with fan motor sub-assembly has a built-in blower controller which is controlled by the air conditioning amplifier.
Bus Connector
The bus connector has a built-in driver IC with a position detection function that communicates with each servo motor connector and actuates the servo motor. This enables bus communication for the servo motor wire harness with a more lightweight construction and a reduced number of wires.
Servo Motor
The pulse pattern type servo motor consists of a printed circuit board and a servo motor. The printed circuit board has 3 contact points, and can transmit 2 on-off signals to the air conditioning amplifier based on the difference in the pulse phases. The bus connector can detect damper position and direction of movement with this signal.
Clean Air Filter
A pollen-removal type clean air filter is used. This filter is made of polyester and excels in the removal of dust and pollen. Because the filter is made of polyester it can be disposed of easily as a non-hazardous combustible material, a feature provided out of consideration for the environment.
| *1 | Clean Air Filter | *2 | Large foreign Object Filter Layer |
| *3 | Electret Layer | - | - |
|
Air Flow | - | - |
The replacement interval for the clean air filter is 30000 km (18000 miles). The cleaning interval for the clean air filter is 10000 km (6000 miles). However, observation of these guidelines should depend on the usage conditions (or environment).
Cooler Condenser Assembly
The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a super-cooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.
In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.
The desiccant and filter at the bottom of the modulator remove moisture and debris from the refrigerant.
| *1 | Modulator | *2 | Desiccant |
| *3 | Filter | - | - |
|
Gaseous Refrigerant |
|
Condensing Portion |
|
Super-cooling Portion |
|
Liquid Refrigerant |
The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system is recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system would be affected. Overcharging the system with refrigerant will also lead to reduced performance. For the proper method of verifying the amount of refrigerant and for instructions on how to recharge the system with refrigerant. For details, refer to the Repair Manual.
Compressor Assembly with Magnet Clutch
A compact, lightweight, and low-noise 10-cylinder swash plate type compressor (10S17) is adopted.
| *1 | Pulley ·
Magnetic Clutch |
*2 | Lock Sensor |
| *3 | Swash Plate | *4 | Swash Plate Chamber |
| *5 | Piston | *6 | Shaft |
| *a | A-A Cross Section | - | - |
Room Temperature Sensor
The room temperature sensor detects the room temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier.
Ambient Temperature Sensor
The ambient temperature sensor detects the ambient temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier.
Solar Sensor (Automatic Light Control Sensor)
The automatic light control sensor consists of a photo diode, 2 amplifier circuits for the solar sensor, and a frequency converter circuit for the light control sensor.
The solar sensor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from its left hand and right hand sides (2 directions) and outputs these sunlight strength signals to the air conditioning amplifier.
OPERATION
Mode Position and Door Operation
| Control Door | Operation Position | Door Position | Operation | |
|---|---|---|---|---|
| Air Inlet Control Door | FRESH | A | Brings in fresh air. | |
| RECIRCULATION | B | Recirculates internal air. | ||
| Air Mix Control Door | MAX COLD to MAX HOT Temperature Setting | C - D - E
(C' - D' - E') |
Varies the mixture ratio of warm air and cool air in order to regulate the temperature continuously between hot and cold. | |
| Mode Control Door |
|
FACE1 | F, J, N | Air blows out of the front center register, side register and rear center register. |
| FACE2 | F, K, N | Air blows out of the front center register, side register and rear center register ducts. In addition, air blows out slightly from the front and rear footwell register ducts. | ||
|
BI-LEVEL | G, L, N | Air blows out of the front and rear center register, side register and front and rear footwell register ducts. | |
|
FOOT | H, M, O | Air blows out of the front and rear footwell register ducts. In addition, air blows out slightly from the front and rear center register, side register and defroster. | |
|
FOOT AND DEFROSTER | H, L, P | Defrosts the windshield through the center defroster, side defroster, side register, front and rear center register ducts, while air is also blown out from the front and rear footwell register ducts. | |
|
DEFROSTER | I, J, Q | Defrosts the windshield through the center defroster, side defroster. | |
Air Outlets and Airflow Volume
DIAGNOSIS
The air conditioning amplifier has a diagnosis function. It stores a record of any air conditioning system failures in its memory in the form of Diagnostic Trouble Codes (DTCs).
There are 2 methods for reading DTCs. One is to use the Techstream, and the other is to read the DTCs using the heater control panel display. For details, refer to the Repair Manual.