Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › CRANKSHAFT POSITION SENSOR
RM1440E _51 Engine / Hybrid System _056124 1GR-FE ENGINE CONTROL _0273868 CRANKSHAFT POSITION SENSOR G

1GR-FE ENGINE CONTROL  CRANKSHAFT POSITION SENSOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT CRANKSHAFT POSITION SENSOR

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 Cold 1630 to 2740 Ω
Hot 2065 to 3225 Ω


NOTICE:

In the table above, the terms "Cold" and "Hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).


If the result is not as specified, replace the sensor.