Home › Engine / Hybrid System › 1GR-FE EMISSION CONTROL › AIR SWITCHING VALVE(for Bank 2) › from 2014.08
RM1440E _51 Engine / Hybrid System _056127 1GR-FE EMISSION CONTROL _0273903 AIR SWITCHING VALVE(for Bank 2) G

1GR-FE EMISSION CONTROL  AIR SWITCHING VALVE(for Bank 2)  INSPECTION  


PROCEDURE

Hide 25702 1.INSPECT NO. 2 EMISSION CONTROL VALVE SET

a.
A289397E02
0.094,0.063 0.302,0.302 0.208,0.24 10 false *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
5 - Body ground


Text in Illustration
*a Component without harness connected
(No. 2 Emission Control Valve Set)

HINT:
·

When measuring the resistance, do not touch terminals 2, 3 or 4.

·

When measuring the resistance, make sure that the surface temperature of the No. 2 emission control valve set is 20°C.



If the result is not as specified, replace the No. 2 emission control valve set.


b.

Check the operation of the No. 2 emission control valve set.

i.
A224406E04
0.948,1.26 1.042,1.26 1.042,1.26 1.115,1.594 false 0.417,2.146 0.51,2.146 0.51,2.146 0.583,1.844 false 1.958,2.177 1.958,2.76 true 0.198,2.073 0.375,2.25 0.177,0.177 10 false *1 0.75,1.188 0.927,1.365 0.177,0.177 10 false *2 1.885,2.771 2.063,2.948 0.177,0.177 10 false *3

Check that air does not flow from port A to port B.

Text in Illustration
*1 Air
*2 Port A
*3 Port B

NOTICE:

Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.


If the result is not as specified, replace the No. 2 emission control valve set.


ii.
A289398E03
0.24,3.208 0.323,3.208 0.323,3.208 0.375,3.448 false 0.552,2.938 0.656,2.938 0.656,2.938 0.76,3.292 false 1.594,3.865 1.51,3.917 1.51,3.917 1.51,4.385 true 0.063,3.146 0.24,3.333 0.177,0.188 10 false *1 0.354,2.844 0.615,3.031 0.26,0.188 10 false *2 1.448,4.427 1.656,4.594 0.208,0.167 10 false *3

Apply battery voltage across terminals 1 and 5.

NOTICE:

When applying voltage, do not touch terminals 2, 3 or 4.



iii.

Check that air flows from port A to port B.

Text in Illustration
*1 Air
*2 Port A
*3 Port B

If the result is not as specified, replace the No. 2 emission control valve set.