Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › TRANSMISSION WIRE
RM1440E _52 Drivetrain _056134 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0273941 TRANSMISSION WIRE G

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  TRANSMISSION WIRE  INSPECTION  


PROCEDURE

Hide 82125J 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

C214326E92
2.229,0.979 2.521,0.438 false 2.156,1.313 2.396,1.771 false 2.083,0.979 1.792,0.438 false 2.01,1.323 1.771,1.781 false 2.406,1.781 2.823,1.948 0.417,0.167 10 false OT2+ 1.49,1.76 1.823,1.927 0.333,0.167 10 false OT+ 0.063,0.042 0.292,0.208 0.229,0.167 10 false *a 2.521,0.229 2.917,0.396 0.396,0.167 10 false OT2- 1.531,0.229 1.823,0.396 0.292,0.167 10 false OT-

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection ATF Temperature Specified Condition
2 (OT-) - 10 (OT+) 10°C (50°F) 5 to 8 kΩ
2 (OT-) - 10 (OT+) 25°C (77°F) 2.5 to 4.5 kΩ
2 (OT-) - 10 (OT+) 110°C (230°F) 0.22 to 0.28 kΩ
1 (OT2-) - 9 (OT2+) 10°C (50°F) 5 to 8 kΩ
1 (OT2-) - 9 (OT2+) 25°C (77°F) 2.5 to 4.5 kΩ
1 (OT2-) - 9 (OT2+) 110°C (230°F) 0.22 to 0.28 kΩ


Text in Illustration
*a Component without harness connected
(Transmission Wire)

HINT:

If the resistance is out of the specified range at one of the ATF temperatures shown in the table below the driveability of the vehicle may decrease.


Resistance (Reference):
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ


If the result is not as specified, replace the transmission wire.