The warning indicator lights are installed in the combination meter assembly.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the F14 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F14-17 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
OK
NG
Disconnect the F78 clearance warning ECU assembly connector.
Disconnect the F14 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F78-9 (L4) - F14-35 (FR) | Always | Below 1 Ω |
| F78-26 (L5) - F14-32 (FL) | Always | Below 1 Ω |
| F78-28 (L1) - F14-7 (RR) | Always | Below 1 Ω |
| F78-29 (L2) - F14-12 (RL) | Always | Below 1 Ω |
| F78-30 (L3) - F14-18 (BK) | Always | Below 1 Ω |
| F78-31 (L10) - F14-31 (OP) | Always | Below 1 Ω |
| F78-9 (L4) - Body ground | Always | 10 kΩ or higher |
| F78-26 (L5) - Body ground | Always | 10 kΩ or higher |
| F78-28 (L1) - Body ground | Always | 10 kΩ or higher |
| F78-29 (L2) - Body ground | Always | 10 kΩ or higher |
| F78-30 (L3) - Body ground | Always | 10 kΩ or higher |
| F78-31 (L10) - Body ground | Always | 10 kΩ or higher |
OK
NG