Home › Power Source / Network › NETWORKING › LIN COMMUNICATION SYSTEM
RM1440E _57 Power Source / Network _056154 NETWORKING _0274052 LIN COMMUNICATION SYSTEM J

NETWORKING  LIN COMMUNICATION SYSTEM  Air Conditioning Control Panel does not Operate  


DESCRIPTION

When a switch of the air conditioning control assembly is operated, the air conditioning control assembly uses LIN communication to communicate with the air conditioning amplifier. If a switch of the air conditioning control assembly does not operate properly, a problem with the LIN communication between the air conditioning control assembly and air conditioning amplifier may be causing the malfunction.

WIRING DIAGRAM

C361648E01
1.573,0.458 1.906,0.656 0.333,0.198 10 false LIN1 2.031,0.323 2.25,0.5 0.219,0.177 10 false 37 4.865,0.333 5.042,0.51 0.177,0.177 10 false 10 5.156,0.427 5.51,0.625 0.354,0.198 10 false LIN1 0.552,1 0.896,1.156 0.344,0.156 10 false F42 0.542,1.208 2.771,1.406 2.229,0.198 10 false Air Conditioning Amplifier Assembly 4.438,1.031 4.75,1.198 0.313,0.167 10 false F29 4.438,1.219 6.604,1.417 2.167,0.198 10 false Air Conditioning Control Assembly

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR CONDITIONING CONTROL)
a.

Disconnect the F42 air conditioning amplifier assembly connector.


b.

Disconnect the F29 air conditioning control assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F42-37 (LIN1) - F29-10 (LIN1) Always Below 1 Ω
F42-37 (LIN1) or F29-10 (LIN1) - Body ground Always 10 kΩ or higher


Result
Result Proceed to
OK (for Automatic Air Conditioning System) A
OK (for Manual Air Conditioning System) B
NG C



A

B

C

REPAIR OR REPLACE HARNESS OR CONNECTOR