When a switch of the air conditioning control assembly is operated, the air conditioning control assembly uses LIN communication to communicate with the air conditioning amplifier. If a switch of the air conditioning control assembly does not operate properly, a problem with the LIN communication between the air conditioning control assembly and air conditioning amplifier may be causing the malfunction.
Disconnect the F42 air conditioning amplifier assembly connector.
Disconnect the F29 air conditioning control assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F42-37 (LIN1) - F29-10 (LIN1) | Always | Below 1 Ω |
| F42-37 (LIN1) or F29-10 (LIN1) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (for Automatic Air Conditioning System) | A |
| OK (for Manual Air Conditioning System) | B |
| NG | C |
A
B
C