81260A
1.INSPECT MAP LIGHT ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 (+B1) - 1 (GND) | Spot light switch off | 10 kΩ or higher |
| Spot light switch on | Below 1 Ω | |
| 9 (+B1) - 6 (CTY) | Not door position | 10 kΩ or higher |
| Door position | Below 1 Ω |
| *a | Component without harness connected
(Map Light Assembly) |
If the result is not as specified, replace the map light assembly.
Apply battery voltage to the connector and check the LED illumination.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 8 (ACC1)
Battery negative (-) → Terminal 10 (CILL) |
LED illuminates |
If the result is not as specified, replace the bulb.