AIR CONDITIONING AMPLIFIER
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| F81-9 (ROUT) - Body ground | LG - Body ground | Output climate control signal (Front passenger side) | Ignition switch to ON
Refreshing seat switch RH blower side level 3 |
Pulse generation
(see waveform 1) |
| F81-10 (LOUT) - Body ground | L - Body ground | Output climate control signal (Driver side) | Ignition switch to ON
Refreshing seat switch LH blower side level 3 |
Pulse generation
(see waveform 1) |
| F81-15 (SW 5) - Body ground | W - Body ground | Input climate control signal (Front passenger side) | Ignition switch to ON
Refreshing seat switch RH level 0 |
4.5 to 5.5 V |
| Ignition switch to ON
Refreshing seat switch RH blower side level 3 |
Below 1 V | |||
| F81-16 (SW 4) - Body ground | V - Body ground | Input climate control signal (Driver side) | Ignition switch to ON
Refreshing seat switch LH level 0 |
4.5 to 5.5 V |
| Ignition switch to ON
Refreshing seat switch LH blower side level 3 |
Below 1 V | |||
| F42-31 (S5-4) - Body ground | V - Body ground | Power supply | Ignition switch to ON | 4.5 to 5.5 V |
| F42-35 (SG-4) - Body ground | SB - Body ground | Ground | Always | Below 1 Ω |
If the result is not as specified, the air conditioning amplifier may have a malfunction.
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | F81-9 (ROUT) - Body ground
F81-10 (LOUT) - Body ground |
| Tool Setting | 2 V/DIV., 500 μsec/DIV. |
| Condition | Ignition switch to ON
Refreshing seat switch blower side level 3 |