Home › Vehicle Interior › HEATING / AIR CONDITIONING › REFRIGERANT
RM1440E _58 Vehicle Interior _056163 HEATING / AIR CONDITIONING _0274136 REFRIGERANT A

HEATING / AIR CONDITIONING  REFRIGERANT  REPLACEMENT  


PROCEDURE

Hide 1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

a.

Start the engine.


b.

Turn the A/C switch on.


c.

Operate the cooler compressor while the engine speed is approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the compressor oil remaining in each component into the cooler compressor.


d.

Stop the engine.


e.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.


Hide 2.CHARGE REFRIGERANT

SST
09985-20010  (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070)

a.

Perform vacuum purging using a vacuum pump.


b.

Charge refrigerant HFC-134a (R134a).

Standard:

550 +/-30 g (19.3 +/-1.0 oz.)


I112466E01
1.854,3.365 2.99,3.542 1.135,0.177 10 false Sub-cool System 3.24,3.188 4.552,3.365 1.313,0.177 10 false Refrigerant Amount 0.354,1.865 1.031,2.271 0.677,0.406 10 false High Pressure 1.521,0.208 3,0.427 1.479,0.219 10 false Amount to be charged 2.198,0.563 3.677,0.781 1.479,0.219 10 false Charge 100 g (3.53 oz.) 3.854,0.281 4.823,0.698 0.969,0.417 10 false Mean value in proper range 3.219,1.49 4.635,1.708 1.417,0.219 10 false +/-50 g (+/-1.76 oz.) 4.729,1.521 5.594,1.729 0.865,0.208 10 false Overcharged 3.458,1.844 4.219,2.417 0.76,0.573 10 false Point where bubbles disappear

NOTICE:
·

Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.

·

Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by measuring its quantity, and not with the sight glass.




Hide 3.WARM UP ENGINE

a.

Warm up the engine at less than 1850 rpm for 2 minutes or more after charging the refrigerant.

NOTICE:

Be sure to warm up the compressor when turning the A/C switch is on after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.



Hide 4.CHECK FOR REFRIGERANT GAS LEAK

a.

After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.


b.

Perform the operation under these conditions:

·

Stop the engine.

·

Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).

·

Repeat the test 2 or 3 times.

·

Make sure that some refrigerant remains in the refrigeration system. When compressor is off: approximately 392 to 588 kPa (4.0 to 6.0 kgf/cm2, 57 to 85 psi).



c.
I042222E47
2.781,1.479 3.281,0.125 3.281,0.125 3.104,0.125 false 2.948,0.042 3.146,0.24 0.198,0.198 10 false *1 0.052,0.063 0.25,0.26 0.198,0.198 10 false *a

Using a halogen leak detector, check the refrigerant line for leakage.

Text in Illustration
*1 Halogen Leak Detector
*a Check for Leakage


d.

If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.


e.

Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.