Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR
RM1440E _58 Vehicle Interior _056163 HEATING / AIR CONDITIONING _0274141 ROOM TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  ROOM TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625Q 1.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)

E201245E01
0.073,0.043 0.313,0.234 0.241,0.191 10 *a 0.07,1.437 0.265,1.585 0.195,0.149 8 4.0 0.07,1.716 0.265,1.865 0.195,0.149 8 3.5 0.07,1.999 0.265,2.148 0.195,0.149 8 3.0 0.07,2.279 0.265,2.428 0.195,0.149 8 2.5 0.07,2.593 0.265,2.742 0.195,0.149 8 2.0 0.07,2.902 0.265,3.051 0.195,0.149 8 1.5 0.07,3.168 0.265,3.317 0.195,0.149 8 1.0 0.07,3.469 0.265,3.618 0.195,0.149 8 0.5 0.07,3.757 0.265,3.906 0.195,0.149 8 0.0 0.28,3.909 0.472,4.054 0.192,0.145 8 10 0.263,4.061 0.488,4.206 0.224,0.145 8 (50) 0.815,3.909 1.007,4.054 0.192,0.145 8 20 0.764,4.061 0.983,4.206 0.220,0.145 8 (68) 1.392,3.909 1.584,4.054 0.192,0.145 8 30 1.358,4.061 1.605,4.206 0.247,0.145 8 (86) 1.973,3.909 2.165,4.054 0.192,0.145 8 40 1.905,4.061 2.197,4.206 0.292,0.145 8 (104) 2.581,3.909 2.772,4.054 0.192,0.145 8 50 2.512,4.061 2.809,4.206 0.296,0.145 8 (122) 3.09,3.909 3.241,4.054 0.150,0.145 8 60 3.034,4.061 3.323,4.206 0.289,0.145 8 (140) 0.561,1.089 0.780,1.273 0.218,0.184 10 *b 1.682,4.302 1.886,4.479 0.205,0.177 10 *c

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


HINT:

As the temperature increases, the resistance decreases (refer to the graph).


NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.


·

When measuring the resistance, the sensor temperature must be the same as the ambient temperature.



If the result is not as specified, replace the cooler thermistor (room temperature sensor).

Text in Illustration
*a Component without harness connected
Cooler Thermistor (Room Temperature Sensor)
*b Resistance (kΩ)
*c Temperature (°C(°F))