Home › Vehicle Interior › HEATING / AIR CONDITIONING › AMBIENT TEMPERATURE SENSOR
RM1440E _58 Vehicle Interior _056163 HEATING / AIR CONDITIONING _0274144 AMBIENT TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  AMBIENT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625P 1.INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)

E353421E01
2.74,0.75 2.885,0.75 2.885,0.75 2.979,1.375 false 0.594,0.542 0.792,0.75 0.198,0.208 10 false *a 2.552,0.667 2.75,0.875 0.198,0.208 10 false *b 4.365,0.094 4.563,0.302 0.198,0.208 10 false *c 3.917,0.302 4.115,0.51 0.198,0.208 10 false 4.0 3.917,0.521 4.115,0.729 0.198,0.208 10 false 3.5 3.906,0.75 4.104,0.958 0.198,0.208 10 false 3.0 3.906,0.979 4.104,1.188 0.198,0.208 10 false 2.5 3.906,1.208 4.104,1.417 0.198,0.208 10 false 2.0 3.896,1.427 4.094,1.635 0.198,0.208 10 false 1.5 3.906,1.656 4.104,1.865 0.198,0.208 10 false 1.0 3.906,1.875 4.104,2.083 0.198,0.208 10 false 0.5 3.906,2.094 4.104,2.302 0.198,0.208 10 false 0.0 4.135,2.24 4.333,2.448 0.198,0.208 10 false 10 4.542,2.24 4.74,2.448 0.198,0.208 10 false 20 5.01,2.229 5.208,2.438 0.198,0.208 10 false 30 5.469,2.219 5.667,2.427 0.198,0.208 10 false 40 5.938,2.219 6.135,2.427 0.198,0.208 10 false 50 6.354,2.219 6.552,2.427 0.198,0.208 10 false 60 4.094,2.396 4.365,2.604 0.271,0.208 10 false (50) 4.5,2.406 4.771,2.615 0.271,0.208 10 false (68) 4.979,2.396 5.25,2.604 0.271,0.208 10 false (86) 5.396,2.385 5.74,2.594 0.344,0.208 10 false (104) 6.281,2.375 6.625,2.583 0.344,0.208 10 false (140) 5.854,2.375 6.198,2.583 0.344,0.208 10 false (122) 5.229,2.583 5.427,2.792 0.198,0.208 10 false *d

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


HINT:

As the temperature increases, the resistance decreases (refer to the graph).


NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.


·

When measuring the resistance, the sensor temperature must be the same as the ambient temperature.



If the result is not as specified, replace the cooler thermistor (ambient temperature sensor).

Text in Illustration
*a Component without harness connected
(Ambient Temperature Sensor)
*b Sensor Area
*c Resistance (kΩ)
*d Temperature (°C(°F))