HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  TERMINALS OF ECU  


CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


U180996E02
5.823,0.188 6.198,0.385 0.375,0.198 10 false z14 3.99,0.188 4.365,0.385 0.375,0.198 10 false F42

a.

Disconnect the F42 amplifier connector.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
F42-21 (B) - F42-14 (GND) V - W-B Battery power source Always 11 to 14 V
F42-1 (IG+) - F42-14 (GND) L - W-B Ignition power supply Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
F42-14 (GND) - Body ground W-B - Body ground Ground for main power supply Always Below 1 Ω

If the result is not as specified, there may be a malfunction on the wire harness side.



c.

Reconnect the F42 amplifier connector.


d.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
F42-5 (TAM) - F42-13 (SG-2) V - G Cooler thermistor (ambient temperature sensor) signal
·

Ignition switch ON

·

Ambient temperature 25°C (77°F)


1.35 to 1.75 V
F42-5 (TAM) - F42-13 (SG-2) V - G Cooler thermistor (ambient temperature sensor) signal
·

Ignition switch ON

·

Ambient temperature 40°C (104°F)


0.9 to 1.2 V
F42-8 (LOCK) - F42-13 (SG-2) R - G A/C compressor lock sensor signal
·

Engine running

·

Blower switch LO

·

A/C switch on


Pulse generation
(See waveform 1)
F42-9 (PRE) - Body ground G - Body ground No. 1 pressure switch signal
·

Ignition switch ON

·

Refrigerant pressure normal (below 3.14 MPa [32.0 kgf/cm2, 455 psi] and higher than 0.196 MPa [2.0 kgf/cm2, 28 psi])


Below 1 V
F42-9 (PRE) - Body ground G - Body ground No. 1 pressure switch signal
·

Ignition switch ON

·

Refrigerant pressure abnormal (below 0.196 MPa [2.0 kgf/cm2, 28 psi] or higher than 3.14 MPa [32.0 kgf/cm2, 455 psi])


4.69 V or higher
F42-17 (AC1) - F42-14 (GND) LG - W-B Compressor operation signal
·

Ignition switch ON

·

A/C switch on


Below 1 V
F42-18 (MHTR) - F42-14 (GND) G - W-B Mirror heater relay signal
·

Ignition switch ON

·

Mirror heater switch on


Below 1 V
F42-20 (MGC) - F42-14 (GND) R - W-B Magnet clutch assembly operation signal
·

Ignition switch ON

·

Blower switch LO

·

A/C switch on


Below 1 V
F42-23 (BLW) - F42-14 (GND) LG - W-B Blower with fan motor sub-assembly control signal
·

Ignition switch ON

·

Blower switch LO


Pulse generation
(See waveform 2)
F42-27 (ACT) - F42-14 (GND) SB - W-B Compressor operation signal
·

Ignition switch ON

·

A/C switch on


4.75 to 5.25 V
z14-2 (BUS G) - Body ground - Ground for BUS IC Always Below 1 V
z14-3 (BUS) - z14-2 (BUS G) - BUS IC control signal Ignition switch ON Pulse generation
z14-4 (B BUS) - z14-2 (BUS G) - Power supply for BUS IC Always 11 to 14 V
z14-6 (TE) - z14-5 (SG) - No. 1 cooler thermistor signal
·

Ignition switch ON

·

Evaporator temperature 0°C (32°F)


1.7 to 2.1 V
·

Ignition switch ON

·

Evaporator temperature 15°C (59°F)


0.9 to 1.3 V

If the result is not as specified, the air conditioning amplifier assembly may have a malfunction.



e.
E116941E07
0.167,0.948 0.531,1.146 0.365,0.198 10 GND

Using an oscilloscope, check waveform 1.

A/C Compressor Lock Sensor Signal
Item Content
Terminal No. (Symbol) F42-8 (LOCK) - F42-13 (SG-2)
Tool Setting 200 mV/DIV., 10 ms./DIV.
Condition
·

Engine running

·

A/C switch on

·

Blower switch LO




f.
E103396E23
2.938,1.646 3.333,1.854 0.396,0.208 10 GND

Using an oscilloscope, check waveform 2.

Blower Motor Control Signal
Item Content
Terminal No. (Symbol) F42-23 (BLW) - F42-14 (GND)
Tool Setting 1 V/DIV., 500 μs/DIV.
Condition
·

Ignition switch ON

·

Blower switch LO



HINT:

When the blower level is increased, the duty ratio changes accordingly.




CHECK HEATER CONTROL ASSEMBLY


U180705E02
3.438,0.188 3.792,0.365 0.354,0.177 10 false F29

a.

Disconnect the F29 control connector.


b.

Measure the resistance and voltage according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
F29-4 (IG+) - F29-11 (GND) L - W-B IG power supply Ignition switch ON 11 to 14 V
F29-11 (GND) - Body ground W-B - Body ground Ground Always Below 1 Ω

If the result is not as specified, there may be a malfunction on the wire harness side.