Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)
RM1440E _58 Vehicle Interior _056163 HEATING / AIR CONDITIONING _0274152 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) D

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  SYSTEM DESCRIPTION  


GENERAL


a.

The air conditioning system has the following controls.

Control Outline
Manual Control The air conditioning amplifier assembly controls the damper positions (air inlet control damper, air mix control damper and mode control damper) and blower speed in accordance with the positions of the switches (temperature control dial, blower dial, mode operation switch and REC/FRS switch).
Air Inlet Control Drives the recirculation damper servo sub-assembly according to the operation of the REC/FRS switch and moves the dampers to the fresh or recirculation position.
Compressor Control The air conditioning amplifier assembly compares the A/C pulley speed signals, which are transmitted by the ECM (crankshaft position sensor). When the air conditioning amplifier assembly determines that the A/C pulley is locked, it turns off the magnet clutch assembly.
Defroster Control Defroster control logic is used to improve defroster performance.
Defroster Fresh Air Mode Switching Control Defroster fresh air mode switching control changes the system from recirculation air mode to fresh air mode to improve defroster performance.
MAX Air Conditioning Control When the temperature control dial is in the MAX A/C position, the air conditioning amplifier assembly turns the air conditioning compressor on and activates the recirculation damper servo sub-assembly to set the air inlet control damper to the recirculation position*, thereby improving cooling efficiency.
Rear Defogger Control When the ignition switch is ON and the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes. However, the operating time of the rear defogger can be extended up to approx. 255 minutes when both of the following requirements are met:
·

Ambient Temperature: 0°C (32°F) or less

·

Vehicle Speed: 50 km/h (31.1 mph) or more


Diagnosis A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system.

*: without DEF, FOOT/DEF mode




MODE POSITION AND DAMPER OPERATION


E203283E03
2.542,3.844 1.76,4.417 1.76,4.417 2.031,4.417 true 1.25,3.948 1.25,3.813 1.25,3.813 2.021,3.406 true 0.323,4.438 0.208,4.438 0.208,4.438 0.823,3.344 true 0.198,1.729 0.76,2.083 0.563,0.354 10 Fresh 2.292,0.115 3.948,0.458 1.656,0.344 10 Front Defroster 0.375,4.354 1.906,5.146 1.531,0.792 10 Blower Motor 4.573,4.75 5.74,5.385 1.167,0.635 10 Rear Footwell Register Duct 3.677,3.688 4.885,4.302 1.208,0.615 10 Front Footwell Register Duct 6.396,3.677 7.115,4.396 0.719,0.719 10 Side Register 4.875,3.677 5.802,4.281 0.927,0.604 10 Front Center Register 0.875,3.979 2.125,4.344 1.25,0.365 10 Evaporator 2.094,4.323 3.25,4.792 1.156,0.469 10 Heater Core 1.26,1.76 2.417,2.031 1.156,0.271 10 Recirculation 5.729,5.313 6.615,6.292 0.885,0.979 10 Rear Face Register 4.156,0.792 5.979,1.24 1.823,0.448 10 Front Defroster 0.344,0.813 2.156,1.365 1.813,0.552 10 Front Defroster

Function of Main Damper
Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper Fresh A Brings in fresh air.
Recirculation B Recirculates internal air.
Air Mix Control Damper MAX COOL to MAX HOT E - D - C Varies the mixture of cold air and hot air in order to regulate the temperature continuously from hot to cool.
MAX COOL Damper MAX COOL V Open in the MAX COOL position.
Except MAX COOL W Close in all position except MAX COOL position.
MAX HOT Damper MAX HOT Y Open in the MAX HOT position.
Except MAX HOT X Closed in all position except MAX HOT position.
Mode Control Damper Face
E264852

F, I, N, T, X Air blows out of the front center registers, side registers and rear face registers.
Bi-level
E264849

G, L, N, T, X Air blows out of the front center registers, side registers, rear face registers and front and rear footwell register ducts.
Foot
E264850

H, M, P, T, W, Y (MAX HOT position)
H, M, O, T, X (Except MAX HOT position)
Air blows out of the front and rear footwell register ducts.
In addition, air blows out slightly from the front defroster, side registers, front center registers and rear face registers.
Foot/Def
E264851

H, K, R, T, W, Y (MAX HOT position)
H, M, Q, T, X (Except MAX HOT position)
Defrosts the windshield through the front defroster and side registers while air is also blown out from the front and rear footwell register ducts.
In addition, air blows out slightly from the front center registers and rear face registers.
Def
E264847

H, I, S, U, X Defrosts the windshield through the front defrosters.


AIR OUTLETS AND AIRFLOW VOLUME


E195820E02
3.854,2.333 4.042,2.552 0.188,0.219 10 true A 2.094,3.865 2.281,4.083 0.188,0.219 10 true C 4.531,3.24 4.677,3.417 0.146,0.177 10 true C 5.302,1.99 5.448,2.167 0.146,0.177 10 false B 1.865,2.896 2.021,3.073 0.156,0.177 10 true B 2.115,1.427 2.26,1.604 0.146,0.177 10 false F 2.667,1.281 2.813,1.458 0.146,0.177 10 false F 3.25,1.167 3.396,1.344 0.146,0.177 10 false F 3.438,2.448 3.583,2.625 0.146,0.177 10 false A 1.042,2.542 1.188,2.719 0.146,0.177 10 false F 5.365,1.406 5.51,1.583 0.146,0.177 10 false F 2.417,3.823 2.604,4.031 0.188,0.208 10 true C 4.177,3.333 4.375,3.542 0.198,0.208 10 true C 5.063,4.219 5.26,4.438 0.198,0.219 10 true D 3.594,5.177 3.74,5.354 0.146,0.177 10 false E 5.406,4.688 5.552,4.865 0.146,0.177 10 false E

Indication
(Mode)
Front Center Register Side Register Front Footwell Register Rear Face Register Rear Footwell Register Front Defroster
A B C D E F
Face
E264852

E324020

E324020

-
E324022

- -
Bi-level
E264849

E324021

E324021

E324021

E324022

E324022

-
Foot
E264850

E324023

E324023

E324020

E324023

E324021

E324023

Foot/Def
E264851

E324023

E324023

E324021

E324023

E324021

E324022

Def
E264847

- - - - -
E324020


HINT:

The size of the circle indicates the proportion of airflow volume.



A/C LOCK SENSOR


The A/C lock sensor sends A/C pulley speed signals to the air conditioning amplifier assembly. The air conditioning amplifier assembly determines whether the A/C compressor is locked or not by using those signals and engine speed signals.


No. 1 COOLER THERMISTOR


The No. 1 cooler thermistor detects the temperature of the cool air immediately after it passes through the evaporator in the form of resistance changes, and outputs the temperature to the air conditioning amplifier assembly.


BLOWER WITH FAN MOTOR SUB-ASSEMBLY


The blower with fan motor sub-assembly has a built-in blower controller, and is controlled by the air conditioning amplifier assembly using duty control.


AIR CONDITIONING HARNESS ASSEMBLY (BUS CONNECTOR)


a.

A BUS connector is used in the wire harness that connects the servo motor to the air conditioning amplifier assembly.

E198942E03
5.021,1.885 4.917,1.344 4.917,1.344 5.01,1.344 false 6.594,1.958 6.51,1.469 6.51,1.469 6.604,1.469 false 2.813,1.042 2.74,0.635 2.74,0.635 2.844,0.635 false 0.479,1.896 0.406,1.49 0.406,1.49 0.5,1.49 false 2.927,2.573 2.708,2.969 2.708,2.969 2.802,2.969 false 0.552,1.417 0.823,1.615 0.271,0.198 10 false *1 5.052,1.26 5.323,1.458 0.271,0.198 10 false *3 2.885,0.552 3.156,0.75 0.271,0.198 10 false *2 6.656,1.396 6.927,1.594 0.271,0.198 10 false *4 2.865,2.885 3.135,3.083 0.271,0.198 10 false *5

Connector Type Connected to
*1: Bus connector Damper servo sub-assembly LH (mode damper servo)
*2: Bus connector Damper servo sub-assembly RH (air mix damper servo)
*3: Bus connector Recirculation damper servo sub-assembly
*4: Bus connector Air conditioning amplifier assembly
*5: Connector No. 1 cooler thermistor


b.

Each BUS connector has a built-in communication/driver IC which communicates with each servo motor connector, actuates the servo motor, and has a position detection function.

E187730E03
4.667,1.031 4.823,0.479 4.823,0.479 4.958,0.479 true 4.531,0.875 4.458,0.531 4.458,0.531 4.198,0.531 true 0.406,2.458 2.938,3.042 2.531,0.583 10 Air Conditioning Amplifier Assembly 1.031,0.865 2.198,1.385 1.167,0.521 10 Communication Circuit 1.417,1.979 1.833,2.26 0.417,0.281 10 CPU 3.146,0.448 4.406,0.813 1.26,0.365 10 BUS Connector 5.01,0.385 7.01,0.698 2.0,0.313 10 Communication/Driver IC 5.75,1.781 6.875,2.208 1.125,0.427 10 Servo Motor



SERVO MOTOR


a.

The pulse pattern type servo motor detects the relative position using 2-bit on/off signals.

The forward and reverse revolutions of this motor are detected using two signals, A and B, which output four types of patterns. The air conditioning amplifier assembly counts the number of pulse patterns in order to determine the stopped position.

E187731E02
2.01,2.667 2.01,0.771 2.01,0.771 1.833,0.771 false 4.219,1.646 3.958,1.646 false 4.219,1.99 3.958,1.99 false 4.208,2.333 3.948,2.333 false 4.896,1.198 4.896,0.427 4.896,0.427 5.219,0.427 false 5.844,1.438 6.115,1.438 true 5.875,2.188 6.156,2.188 6.156,2.188 6.156,2.292 true 2.521,2.979 3.406,3.167 0.885,0.188 10 Pattern Width 4.729,4.042 6.458,4.438 1.729,0.396 10 Pattern Width 2.81° 0.542,0.688 1.927,1.177 1.385,0.49 10 Rotation Direction of Printed Board 5.271,0.333 6.635,0.927 1.365,0.594 10 Rotation Direction of Printed Board 5.99,2.385 7.083,3.115 1.094,0.729 10 Pattern (Conductive Part) 6.146,1.365 6.844,1.813 0.698,0.448 10 Printed Board 2.479,1.146 3.969,1.5 1.49,0.354 10 Fixed Contact Point 0.365,3.083 1.146,3.583 0.781,0.5 10 GND 3.656,1.906 4.51,2.26 0.854,0.354 10 GND 3.958,2.75 4.313,3.0 0.354,0.25 10 Hi 3.958,2.948 4.417,3.25 0.458,0.302 10 Lo 3.958,3.24 4.271,3.479 0.313,0.24 10 Hi 3.958,3.448 4.344,3.719 0.385,0.271 10 Lo 0.542,2.688 0.844,2.958 0.302,0.271 10 A 0.542,2.333 0.844,2.573 0.302,0.24 10 B 3.823,1.552 4.333,1.854 0.51,0.302 10 A 3.792,2.823 4.135,3.229 0.344,0.406 10 A 3.823,2.25 4.146,2.49 0.323,0.24 10 B 3.781,3.333 4.094,3.792 0.313,0.458 10 B



COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)


The cooler thermistor (ambient temperature sensor) detects the outside temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.