DTC P0711 Transmission Fluid Temperature Sensor "A" Performance |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0711 | Either condition is met: 1. Conditions (a), (b) and (c) are detected (2-trip detection logic): (a) After the engine is stopped, 5 hours or more elapse before the engine is started. (b) Intake air and engine coolant temperatures are 15°C (59°F) or higher after the engine is started. (c) ATF temperature is below 20°C (68°F) after 16 min. and 40 sec. or more have passed after the engine is started and the vehicle has been driven for 7.5 km (4.6 miles) or more. 2. Conditions (a) and (b) are detected (2-trip detection logic): (a) Engine coolant temperature is below 35°C (95°F) after the engine is started. (b) ATF temperature is 95°C (203°F) or higher when the engine coolant temperature reaches 60°C (140°F) after 10 sec. or more. | No. 1 ATF temperature sensor (transmission wire) |
| Related DTCs | P0711: ATF temperature sensor/Rationality check |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 3 sec. |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | P0712, P0713, P2740, P2742, P2743 (ATF temperature sensor "A" circuit) P0128 (ECT (Engine Coolant Temperature) sensor circuit) P0111, P0112, P0113, P011B, (IAT (Intake Air Temperature) sensor circuit) |
| Soak time | 5 hours or more |
| Duration time from engine start | 12 sec. or more |
| Time after engine start | 16 min. and 40 sec. |
| Driving distance after engine start | 7.5 km (4.6 miles) or more |
| IAT (12 sec. after engine start) | 15°C (59°F) or higher |
| ECT (12 sec. after engine start) | 15°C (59°F) or higher |
| Duration time for ECT to reach 60°C (140°F) | 10 sec. or more |
| ATF temperature (12 sec. after engine start) | 95°C (203°F) or higher |
| ECT (12 sec. after engine start) | Below 35°C (95°F) |
| ATF temperature | Below 20°C (68°F) |
| ATF temperature | 95°C (203°F) or higher |
| ATF temperature | 20°C (68°F) or higher |
| ATF temperature | Below 95°C (203°F) |
| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If the value is -40°C (-40°F) or 215°C (419°F), the No. 1 ATF temperature sensor circuit is open or shorted. |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or higher | Short circuit |
| 1.CHECK DTC OUTPUT (IN ADDITION TO DTC P0711) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs using the Techstream.
| Result | Proceed to |
| Only P0711 is output | A |
| P0711 and other DTCs are output | B |
|
| ||||
| A | |
| 2.CHECK TRANSMISSION FLUID LEVEL |
Check the transmission fluid level (Click here).
|
| ||||
| OK | ||
| ||