DTC P2714 Pressure Control Solenoid "D" Performance (Shift Solenoid Valve SLT) |

| DTC Code | DTC Detection Condition | Trouble Area |
| P2714 | The ECM detects a malfunction of SLT (ON side) according to the difference in speed between the turbine and output shaft, and also by the oil pressure (2-trip detection logic). |
|
| Related DTCs | P2714: Shift solenoid valve SLT/Functional check |
| Required sensors/Components | Shift solenoid valve SLT, Valve body, ATF temperature sensor, Speed sensor (NT), Speed sensor (NO) |
| Frequency of operation | Continuous |
| Duration | Immediate |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | P0717 (Turbine speed sensor circuit) P0722 (Output speed sensor circuit) P0712, P0713, P2740, P2742, P2743 (ATF temperature sensor "A" circuit) P0973, P0974 (Shift solenoid valve S1 circuit) P0976, P0977 (Shift solenoid valve S2 circuit) P0985, P0986 (Shift solenoid valve SR circuit) P0748 (Shift solenoid valve SL1 circuit) P0778 (Shift solenoid valve SL2 circuit) P2716 (Shift solenoid valve SLT circuit) P0128 (ECT (Engine Coolant Temperature) sensor circuit) P0327, P0328, P0332, P0333 (KCS sensor circuit) |
| ETCS (Electric Throttle Control System) | Not system down |
| Transmission position | "D" |
| Duration time from shifting "N" to "D" | 4 sec. or more |
| ECT | 40°C (104°F) or higher |
| Spark advance from max. retard timing by KCS control | 0° crankshaft angle or more |
| Engine | Starting |
| Summation of C1 clutch heat generations | Specified value |
| Shift solenoid valve S1 ON malfunction | Detected |
| Shift solenoid valve S2 ON malfunction | Detected |
| Shift solenoid valve SR OFF malfunction | Detected |
| 1-2 shift valve malfunction | Detected |
| Shift solenoid valve SL1 OFF malfunction | Detected |
| Shift solenoid valve SL2 ON malfunction | Detected |
| 1.CHECK DTC OUTPUT (IN ADDITION TO DTC P2714) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs using the Techstream.
| Result | Proceed to |
| Only P2714 is output | A |
| P2714 and other DTCs are output | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM (SHIFT SOLENOID VALVE SLT) |
![]() |
Remove the test plug from the transmission case and connect SST.
Connect the Techstream to the DLC3.
Start the engine and warm it up.
Measure the line pressure with SST.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the Techstream, perform the Active Test.
Measure the line pressure.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Activate the Solenoid (SLT)* | Operate shift solenoid SLT and raise line pressure | ON or OFF
| [Vehicle Condition]
|
|
| ||||
| OK | |
| 3.PERFORM ACTIVE TEST USING TECHSTREAM (RUNNING TEST) |
Connect the Techstream to the DLC3.
Clear the DTCs (Click here).
Warm up the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the Techstream, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Control the Shift Position | Operate shift solenoid valve and set each shift position |
| Possible to check operation of the shift solenoid valves. [Vehicle Condition] 50 km/h (31 mph) or less. |
Compare the ECM gear shift command and the actual gear position.
| System Condition | ECM Gear Shift Command | Proceed to | ||||||
| 1st | 2nd | 3rd | 4th | 5th | ||||
| Malfunction | Shift solenoid S1 | Stuck ON | 1st | 2nd | 2nd | 1st | N*1 | A |
| Stuck OFF | 4th | 3rd | 3rd | 4th | 5th | |||
| Shift solenoid S2 | Stuck ON*2 | 2nd | 2nd | 3rd | 3rd | N*1 | B | |
| Stuck OFF*3 | 1st | 1st | 4th | 4th | 5th | |||
| Shift solenoid SL2 | Stuck ON | 1st | 2nd | 3rd | 4th | N*1 | C | |
| Stuck OFF | 1st | 2nd | 3rd | 4th | 5th | |||
| Shift solenoid SR | Stuck ON*4 | 1st | 2nd | 3rd | 4th | 5th | D | |
| Stuck OFF*5 | 1st | 2nd | 3rd | 4th | 4th | |||
| Normal | 1st | 2nd | 3rd | 4th | 5th | E | ||
|
| ||||
|
| ||||
|
| ||||
|
| ||||
| A | |
| 4.INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Remove shift solenoid valve S1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve S1) |
|
| ||||
| OK | |
| 5.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 6.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 7.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 -2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
|
| ||||
| OK | |
| 8.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 9.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 10.INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Remove shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve S2) |
|
| ||||
| OK | |
| 11.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 12.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 13.INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Remove shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve SL2) |
|
| ||||
| OK | |
| 14.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 15.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 16.INSPECT SHIFT SOLENOID VALVE SR |
![]() |
Remove shift solenoid valve SR.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve SR connector terminal - Shift solenoid valve SR body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve SR) |
|
| ||||
| OK | |
| 17.INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Remove shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve SL1) |
|
| ||||
| OK | |
| 18.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 19.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||
| 20.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 -2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes operating noise |
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
|
| ||||
| OK | |
| 21.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 22.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||