Home › Drivetrain · A750E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

Refer to DTC P2714 .

DTC Code
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in the shift solenoid valve SLT circuit for 1 sec. or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY


Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
1 sec.
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not stored
None
Solenoid current cut status
Not cut
Battery voltage
8 V or higher
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Output signal monitor
No signal

COMPONENT OPERATING RANGE


Output signal duty
Less than 100%

WIRING DIAGRAM


C161203E89


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    C214326E07
  1. Disconnect the B32 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    14 (SLT+) - 6 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    14 (SLT+) - Body ground
    Always
    10 kΩ or higher
    6 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C214336E02
  1. Disconnect the B37 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B37-34 (SLT+) - B37-35 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    B37-34 (SLT+) - Body ground
    Always
    10 kΩ or higher
    B37-35 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SLT


    C209928E05
  1. Remove shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 -2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SLT)


NG
REPLACE SHIFT SOLENOID VALVE SLT
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)