Home › Drivetrain · A750E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0985    Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)

DTC    P0986    Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which is controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly. In case of an open or short circuit, the ECM stops sending current to the circuit. For details, refer to the fail-safe chart (Click here).

DTC Code
DTC Detection Condition
Trouble Area
P0985
The ECM detects a short in the solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic).
  1. Short in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. ECM
P0986
The ECM detects an open in the solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic).
  1. Open in shift solenoid valve SR circuit
  2. Shift solenoid valve SR
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve SR is on, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.
When the shift solenoid valve SR is off, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve SR circuit (Click here).

MONITOR STRATEGY


Related DTCs
P0985: Shift solenoid valve SR/Range check (Low resistance)
P0986: Shift solenoid valve SR/Range check (High resistance)
Required sensors/Components
Shift solenoid valve SR
Frequency of operation
Continuous
Duration
0.128 sec. or more
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever the following DTCs are not stored
None
Battery voltage
8 V or higher
Ignition switch
ON
Starter
OFF

P0985: Range Check (Low Resistance) 
Shift solenoid valve SR
ON

P0986: Range Check (High Resistance) 
Shift solenoid valve SR
OFF

TYPICAL MALFUNCTION THRESHOLDS


P0985: Range Check (Low Resistance) 
Shift solenoid valve SR resistance
8 Ω or less

P0986: Range Check (High Resistance) 
Shift solenoid valve SR resistance
100 kΩ or higher

COMPONENT OPERATING RANGE


Shift solenoid valve SR resistance
11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM


C161204E81


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


HINT:
The shift solenoid valve SR turns ON/OFF normally when the shift lever is in D.

ECM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SR
OFF
OFF
OFF
OFF
ON

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)


    C214326E06
  1. Disconnect the B32 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    7 (SR) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C214335E02
  1. Disconnect the B36 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B36-31 (SR) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SR


    C214329E01
  1. Remove shift solenoid valve SR.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve SR connector terminal - Shift solenoid valve SR body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve SR connector
    2. Battery negative (-) → Shift solenoid valve SR body
    Valve moves and makes operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SR)


NG
REPLACE SHIFT SOLENOID VALVE SR
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)