Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Entire Combination Meter does not Operate

for Preparation Click here


DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is turned to ON, the indicators will not operate.

WIRING DIAGRAM


E200739E01


INSPECTION PROCEDURE

1.CHECK HARNESS AND CONNECTOR


    E200096E02
  1. Disconnect the F14 meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F14-20 (E1) - Body ground
    Always
    Below 1 Ω
    F14-13 (MGND) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    F14-17 (IG+) - Body ground
    Ignition switch ON
    11 to 14 V
    F14-15 (B) - Body ground
    Always
    11 to 14 V

Text in Illustration 
*a
Front view of wire harness connector
(to Combination Meter Assembly)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)