COMPRESSOR > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
When replacing the compressor and magnetic clutch with a new one, gradually discharge the refrigerant gas from the service valve and drain the following amount of oil from the new compressor and magnetic clutch before installation.
| 2. INSTALL COOLER COMPRESSOR ASSEMBLY |
![]() |
Install the cooler compressor with the stud bolt.
Install the 3 bolts and nut.
Connect the connector.
| 3. CONNECT SUCTION HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the suction hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring to the suction hose.
![]() |
Connect the suction hose with the 2 bolts.
| 4. CONNECT DISCHARGE HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the cooler refrigerant discharge hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring to the discharge hose.
Connect the discharge hose to the cooler compressor with the bolt.
| 5. INSTALL GENERATOR ASSEMBLY |
Install the generator assembly (Click here).
| 6. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 7. WARM UP ENGINE |
Warm up the engine at less than 1850 rpm for 2 minutes or more after charging the refrigerant.
| 8. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a halogen leak detector, check the refrigerant line for leakage.
| *1 | Halogen Leak Detector |
| *a | Check for Leakage |
If a gas leak from the drain hose is not detected, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.