Home › Vehicle Interior › HEATING / AIR CONDITIONING › CONDENSER

CONDENSER > INSTALLATION

for Preparation Click here



1. INSTALL COOLER DRYER
  1. Using pliers, install the cooler dryer.



    E055408E01
  1. Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the cap.

  1. Using a 14 mm socket hexagon wrench, install the cap to the modulator.

    Torque:
    2.9 N*m{ 30 kgf*cm , 26 in.*lbf }



2. INSTALL COOLER CONDENSER ASSEMBLY


    E202537E01
  1. Install the cooler condenser with the 3 bolts as shown in the illustration.

    Torque:
    for bolt A:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }
    for bolt B:
    4.4 N*m{ 44 kgf*cm , 39 in.*lbf }



3. CONNECT NO. 1 COOLER CONDENSER BRACKET
  1. Connect the No. 1 cooler condenser bracket with the bolt.



4. CONNECT NO. 2 COOLER CONDENSER BRACKET
  1. Connect the No. 2 cooler condenser bracket with the bolt.



5. CONNECT COOLER REFRIGERANT LIQUID PIPE A
  1. Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the liquid pipe A joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to liquid pipe A.

  1. Connect liquid pipe A to the cooler condenser with the bolt.

    Torque:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }

    NOTICE:
    1. When tightening the bolts, do not allow any tools to contact the pipe.
    2. When tightening the bolts, hold a part of the pipe near the connector.



6. CONNECT DISCHARGE HOSE SUB-ASSEMBLY
  1. Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the discharge hose joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the discharge hose.

  1. Connect the discharge hose to the cooler condenser with the bolt.

    Torque:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }

    NOTICE:
    1. When tightening the bolt, do not allow any tools to contact the pipe.
    2. When tightening the bolt, hold a part of the pipe near the connector.



7. CHARGE REFRIGERANT
SST
09985-20010   (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070)
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Standard:
    550 +/-30 g (19.3 +/-1.0 oz.)



    I037365E19

    NOTICE:
    1. Do not operate the cooler compressor before charging refrigerant as the cooler compressor does not work properly without any refrigerant and overheats.
    2. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear.



8. INSTALL RADIATOR ASSEMBLY
  1. Install the radiator assembly (Click here).



9. ADD ENGINE COOLANT
  1. Add the engine coolant (Click here).



10. WARM UP ENGINE
  1. Warm up the engine at less than 1850 rpm for 2 minutes or more after charging the refrigerant.

    NOTICE:
    Be sure to warm up the compressor by turning the A/C switch on after removing and installing the cooler refrigerant lines (including the compressor) to prevent damage to the compressor.



11. CHECK FOR ENGINE COOLANT LEAK
  1. Check for engine coolant leak .



12. CHECK FOR REFRIGERANT GAS LEAK
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation under these conditions:

    1. Stop the engine.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
    3. Repeat the test 2 or 3 times.
    4. Make sure that some refrigerant remains in the refrigeration system. When the compressor is off: approximately 392 to 588 kPa (4.0 to 6.0 kgf/cm2, 57 to 85 psi).



    I042222E34
  1. Using a halogen leak detector, check the refrigerant line for leakage.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *a
    Check for Leakage

  1. If a gas leak from the drain hose is not detected, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.

  1. Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.