CONDENSER > INSTALLATION |
| 1. INSTALL COOLER DRYER |
Using pliers, install the cooler dryer.
![]() |
Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.
Install the O-ring to the cap.
Using a 14 mm socket hexagon wrench, install the cap to the modulator.
| 2. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser with the 3 bolts as shown in the illustration.
| 3. CONNECT NO. 1 COOLER CONDENSER BRACKET |
Connect the No. 1 cooler condenser bracket with the bolt.
| 4. CONNECT NO. 2 COOLER CONDENSER BRACKET |
Connect the No. 2 cooler condenser bracket with the bolt.
| 5. CONNECT COOLER REFRIGERANT LIQUID PIPE A |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the liquid pipe A joint.
Install the O-ring to liquid pipe A.
Connect liquid pipe A to the cooler condenser with the bolt.
| 6. CONNECT DISCHARGE HOSE SUB-ASSEMBLY |
Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the discharge hose joint.
Install the O-ring to the discharge hose.
Connect the discharge hose to the cooler condenser with the bolt.
| 7. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 8. INSTALL RADIATOR ASSEMBLY |
Install the radiator assembly (Click here).
| 9. ADD ENGINE COOLANT |
Add the engine coolant (Click here).
| 10. WARM UP ENGINE |
Warm up the engine at less than 1850 rpm for 2 minutes or more after charging the refrigerant.
| 11. CHECK FOR ENGINE COOLANT LEAK |
Check for engine coolant leak .
| 12. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a halogen leak detector, check the refrigerant line for leakage.
| *1 | Halogen Leak Detector |
| *a | Check for Leakage |
If a gas leak from the drain hose is not detected, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.