GENERATOR > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. DISCONNECT CABLE FROM POSITIVE BATTERY TERMINAL |
| 3. REMOVE BATTERY CLAMP |
![]() |
Loosen the 2 nuts and remove the battery clamp.
| 4. REMOVE BATTERY |
| 5. REMOVE BATTERY TRAY |
| 6. REMOVE V-BANK COVER |
![]() |
Raise the front of the V-bank cover to detach the 2 pins. Then detach the 2 V-bank cover hooks from the bracket, and remove the V-bank cover.
| *1 | Pin |
| *2 | V-bank Cover Hook |
| 7. REMOVE FAN AND GENERATOR V BELT |
![]() |
While turning the belt tensioner counterclockwise, align the service hole for the belt tensioner and the belt tensioner fixing position, and then insert a bar of φ 6 mm (0.236 in.) into the service hole to fix the belt tensioner in place.
Remove the V belt.
| 8. REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY |
![]() |
for Integrated Type:
Remove the bolt and No. 2 idler pulley.
for Separate Type:
Remove the bolt, No. 2 idler pulley cover plate, No. 2 idler pulley and idler pulley cover plate.
| 9. REMOVE WIRING HARNESS CLAMP BRACKET |
![]() |
Detach the clamp.
Remove the bolt and wiring harness clamp bracket.
| 10. REMOVE NO. 2 EXHAUST MANIFOLD HEAT INSULATOR |
![]() |
Remove the 3 bolts and No. 2 exhaust manifold heat insulator.
| 11. REMOVE GENERATOR ASSEMBLY |
![]() |
Open the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Disconnect the generator connector from the generator assembly.
![]() |
Remove the 2 bolts and disconnect the wire harness.
![]() |
Disconnect the wire harness clamp.
Remove the bolt and disconnect the generator bracket.
![]() |
Remove the 2 bolts and generator assembly.
![]() |
Remove the bolt and generator bracket.