DTC 62 Motor LH Current Senser |
DTC 63 Motor RH Current Senser |
| DTC No. | Detection Condition | Trouble Area |
| 61 | When the side auto step motor assembly LH is operating, there is less than 1 A of current detected in the side auto step ECU even when the hall effect pluses are input. |
|
| 62 | When the side auto step motor assembly RH is operating, there is less than 1 A of current detected in the side auto step ECU even when the hall effect pluses are input. |

| 1.CHECK HARNESS AND CONNECTOR (SIDE AUTO STEP MOTOR - SIDE AUTO STEP CONTROLLER ECU) |
Disconnect the O25*1 or N23*2 side auto step motor assembly connector.
Disconnect the A42 side auto step controller ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O25-4 (STW1) - A42-3 (STW1) | Always | Below 1 Ω |
| O25-5 (DPL1) - A42-4 (DPL1) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| N23-4 (STW2) - A42-2 (STW2) | Always | Below 1 Ω |
| N23-5 (DPL2) - A42-1 (DPL1) | Always | Below 1 Ω |
|
| ||||
| OK | |
| 2.PERFORM COOL DOWN |
Do not operate the automatic running board in order to cool down the side auto step motor assembly.
| NEXT | |
| 3.CHECK DTC |
Recheck for DTCs and check if the same DTC is output again.
|
| ||||
| OK | ||
| ||