POWER WINDOW CONTROL SYSTEM > INITIALIZATION |
| INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY OR POWER WINDOW REGULATOR SWITCH ASSEMBLY) |
Initialization procedure
Close the door and turn the ignition switch to ON.
![]() |
Open the door glass halfway as shown in the illustration.
Control the power window regular switch (hold down AUTO UP) to fully close the door glass, and then hold the switch for at least 1 second to reset the door glass position and to complete the initialization.