DTC B1430/21 Open in Room Temperature Sensor Circuit |
DTC B1431/-21 Short in Room Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1430/21 | Open in room temperature sensor circuit |
|
| B1431/-21 | Short in room temperature sensor circuit |
|

| 1.READ VALUE USING GTS |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor (Room Temp) | Room Temperature Sensor / min.: -72.47°C (-98.4°F) max.: 193.82°C (380.9°F) | Actual cabin temperature displayed | - |
| Result | Proceed to |
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK FOR DTC |
Clear the DTCs .
Check the DTCs .
|
| ||||
| OK | ||
| ||
| 3.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR |
Remove the cooler (room temp. sensor) thermistor (Click here).
Inspect the cooler (room temp. sensor) thermistor .
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING CONTROL ASSEMBLY) |
Disconnect the D20 air conditioning control assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D67-1 - D20-5(TR) | Always | Below 1 Ω |
| D67-2 - D20-6(SG) | Always | Below 1 Ω |
| D67-1 - Body ground | Always | 10 kΩ or higher |
| D67-2 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||