POWER WINDOW CONTROL SYSTEM > Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) |
| 1.PERFORM INITIALIZATION (APPLICABLE LOCATION) |
Initialize the power window regulator motor assembly (applicable location) (Click here).
Check that all the power windows move when the auto up and down function of the power window regulator master switch assembly and power window regulator switch assemblies are operated (Click here).
|
| ||||
| OK | ||
| ||
| 2.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION) |
Remove the window regulator motor assembly.
Install the window glass onto the weatherstrip.
Check if the door window regulator operates smoothly.
Check that the window glass slides smoothly when sliding it up by hand.
|
| ||||
| OK | ||
| ||