Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

DTC    B1509    Open in Ambient Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The thermistor assembly is installed in the front part of the cooler condenser assembly to display the ambient temperature on the multi-information display in the combination meter assembly and to control the air conditioning auto mode. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies a voltage (5 V) to the thermistor assembly and reads the voltage changes as changes in the resistance of the thermistor assembly.

DTC No.
DTC Detection Condition
Trouble Area
B1509
An open or short in the thermistor assembly circuit.
  1. Thermistor assembly
  2. Harness or connector
  3. Combination meter assembly

WIRING DIAGRAM


E185871E02


INSPECTION PROCEDURE

1.READ VALUE USING GTS (AMBIENT TEMPERATURE SENSOR)
  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. According to the display on the GTS, read the Data List.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temperature
    Thermistor assembly /
    Min: -40.0°C (-40.0°F)
    Max: 87.5°C (189.5°F)
    Actual ambient temperature displayed
    Open in the circuit: -40.0°C (-40.0°F)
    Short in the circuit: 87.5°C (189.5°F)

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to the DTC)
    A
    OK (When troubleshooting according to problem symptoms table)
    B
    NG
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
Go to step 3
A


2.CHECK FOR DTC
  1. Clear the DTCs (Click here).

  1. Check for DTCs (Click here).

OK:
DTC B1509 is not output



NG
REPLACE COMBINATION METER ASSEMBLY (Click here)
OK

END 

3.INSPECT THERMISTOR ASSEMBLY
  1. Remove the thermistor assembly (Click here).

  1. Inspect the thermistor assembly (Click here).



NG
REPLACE THERMISTOR ASSEMBLY (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - COMBINATION METER ASSEMBLY)
  1. Disconnect the A48 thermistor assembly connector.

  1. Disconnect the D7 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    A48-1 - D7-24 (TAM)
    Always
    Below 1 Ω
    A48-2 - D7-25 (SG-)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    A48-1 - Body ground
    Always
    10 kΩ or higher
    A48-2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK