DTC B1014 ACC Power Supply Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1014 | When ACC voltage is 8.3 V or less, or 16.7 V or more (ACC circuit malfunction) |
|

| 1.CLEAR DTC |
Clear the DTCs (Click here).
| NEXT | |
| 2.CHECK FOR DTC |
Check for DTCs (Click here).
| Result | Proceed to |
| DTC B1014 is output | A |
| DTC is not output | B |
|
| ||||
| A | |
| 3.CHECK HARNESS AND CONNECTOR (VOLTAGE) |
Disconnect the 3A and 3E instrument panel junction block assembly connector.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3A-20 - Body ground | Ignition switch ACC | 11 to 14 V |
| 3E-1 - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector (to Instrument Panel Junction Block Assembly) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (GROUND) |
Disconnect the D6 and A73 main body ECU (network gateway ECU) connector.
Disconnect the 3A and 3B instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D6-1 (GND) - Body ground | Always | Below 1 Ω |
| A73-4 (GND) - Body ground | Always | Below 1 Ω |
| 3A-12 - Body ground | Always | Below 1 Ω |
| 3A-13 - Body ground | Always | Below 1 Ω |
| 3B-18 - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3E-1 - MB-9 (ACC) | No battery voltage is applied across terminals 3A-20 and 3A-12 | 10 kΩ or higher |
| 3E-1 - MB-9 (ACC) | Battery voltage is applied across terminals 3A-20 and 3A-12 | Below 1 Ω |
| 3B-18 - MB-11 (GND) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||