Home › General › SPECIFICATIONS › FA20 BATTERY / CHARGING › 2012.03–2019.03
RM2090E _V1 General _060663 SPECIFICATIONS _0297446 FA20 BATTERY / CHARGING F

SPECIFICATIONS  FA20 BATTERY / CHARGING  SERVICE DATA  


Charging circuit without load Standard amperage: 10 A or less
Standard voltage: 11.3 to 15.6 V
Charging circuit with load Standard amperage: 30 A or higher
Brush length Standard length: 22.5 mm (0.885 in.)
Minimum exposed length: 5.0 mm (0.196 in.)
Generator rotor assembly Slip ring resistance: 2.0 to 2.4 kΩ at 20°C (68°F)
Standard slip ring diameter: 22.7 mm (0.893 in.)
Minimum slip ring diameter: 22.1 mm (0.870 in.)