1.INSPECT HEATED OXYGEN SENSOR
Measure the resistance according to the value(s) the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68 °F) | 5.0 to 6.4 Ω |
| 1 - 4 | Always | 10 kΩ or higher |
| *a | Component without harness connected
(Heated Oxygen Sensor) |
If the result is not as specified, replace the heated oxygen sensor.