FA20 ENGINE CONTROL  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT EFI MAIN 1 RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the EFI main 1 relay.


Hide 2.INSPECT EFI MAIN 2 RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the EFI main 2 relay.


Hide 3.INSPECT EFI MAIN 3 RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the EFI main 3 relay.


Hide 4.INSPECT IG2 RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the IG2 relay.


Hide 5.INSPECT INJ RELAY

a.
E209495

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the INJ relay.


Hide 6.INSPECT ETCS RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the ETCS relay.


Hide 7.INSPECT C/OPEN RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to 1 and 2 terminals 10 kΩ or higher
Battery voltage applied to 1 and 2 terminals Below 1 Ω


If the result is not as specified, replace the C/OPEN relay.