16361A
1.INSTALL FAN AND GENERATOR V BELT
Set the fan and generator V belt onto every part.
| *1 | Idler |
| *2 | Generator |
| *3 | Tensioner |
| *4 | Water Pump |
| *5 | Crankshaft |
| *6 | A/C Compressor (w/ Air Conditioning System) |
| Idler Pulley Bracket (w/o Air Conditioning System) |
While turning the belt tensioner clockwise, remove the 3 mm (0.118 in.) hexagon wrench.
Make sure that the fan and generator V belt is properly installed to each pulley.
Check that the fan and generator V belt fits properly in the ribbed grooves.
Make sure to check by hand that the fan and generator V belt have not slipped out of the grooves on the bottom of the pulley.
27029A
2.INSTALL BELT GENERATOR COVER
Install the belt generator cover with the 2 blots.
Engage the 2 wire harness clamps and install the wire harness to the belt generator cover.
27029
3.INSTALL GENERATOR COVER
Install the generator cover with the 2 blots.
17705
4.INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
Install the air cleaner cap with air cleaner hose with the 3 blots.
Install the air cleaner cap with air cleaner hose with the 2 hose clamps.
Connect the No. 2 ventilation hose.
Connect the mass air flow meter connector.
Engage the wire harness clamp and install the wire harness to the air cleaner cap.