89458
1.INSPECT FUEL PRESSURE SENSOR
Check the fuel pressure sensor output voltage.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (VOUT1) - 2 (GND) | Apply 5 V between terminals 4 (VCC) and 2 (GND) | Approximately 0.5 V |
| *a | Component without harness connected
(Fuel Pressure Sensor) |
Be careful when connecting the leads, as the fuel pressure sensor may be damaged if the leads are connected to the wrong terminals.
Do not apply a voltage of 6 V or more to the terminals 4 (VCC) and 2 (GND).
If a stable power supply is not available, use 4 1.2 V nickel-metal hydride batteries, etc.
If the resistance is not as specified, replace the fuel pressure sensor.