16331A
1.INSPECT THERMOSTAT
Immerse the thermostat in water and then gradually heat the water.
Hold the thermostat with a wire or the like, so that the thermostat does not come into contact with the bottom of the container.
Check the valve opening temperature of the thermostat.
86 to 90 °C (187 to 194 °F)
If the valve opening temperature is not as specified, replace the thermostat.
Check the valve opening temperature.
Check the valve lift.
| *a | Valve lift |
8.0 mm (0.315 in.) or more at 95 °C (203 °F)
If the valve lift value is not as specified, replace the thermostat.
When the temperature of the thermostat drops below 83 °C (181 °F), check that the valve is fully closed.
If the valve is not fully closed, replace the thermostat.