16331A
1.INSPECT THERMOSTAT
Immerse the thermostat in water and then gradually heat the water.
Hold the thermostat with a wire or the like, so that the thermostat does not come into contact with the bottom of the container.
Check the valve opening temperature of the thermostat.
48 to 52°C (118 to 126°F)
If the valve opening temperature is not as specified, replace the thermostat.
Check the valve lift.
| *a | Valve Lift |
6.0 mm (0.236 in.) or more at 63°C (145°F)
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the water inlet with thermostat is at low temperatures (below 45°C (113°F)).
If it is not fully closed, replace the thermostat.