Home › Engine / Hybrid System › FA20 COOLING › RELAY
RM2090E _51 Engine / Hybrid System _060670 FA20 COOLING _0297527 RELAY G

FA20 COOLING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85927 1. FAN NO. 1 RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the relay.



Hide 85927A 2. FAN NO. 2 RELAY

a.
A159206E28
2.031,0.656 1.792,0.458 1.792,0.458 1.656,0.458 true 2.302,0.646 2.385,0.229 2.385,0.229 2.469,0.229 true 2.604,0.677 2.833,0.542 2.833,0.542 2.958,0.542 true 2.396,1.135 2.979,1.135 true 2.385,1.635 2.99,1.635 true 0.177,0.927 0.333,1.104 0.156,0.177 10 false 5 0.188,1.344 0.344,1.521 0.156,0.177 10 false 1 0.688,0.333 0.844,0.51 0.156,0.177 10 false 4 1.188,0.917 1.344,1.094 0.156,0.177 10 false 3 1.188,1.323 1.344,1.5 0.156,0.177 10 false 2 1.49,0.375 1.646,0.552 0.156,0.177 10 false 1 2.521,0.135 2.677,0.313 0.156,0.177 10 false 4 3.01,0.458 3.167,0.635 0.156,0.177 10 false 2 3.042,1.542 3.198,1.719 0.156,0.177 10 false 3 3.042,1.042 3.198,1.219 0.156,0.177 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage is not applied between terminals 1 and 2 Below 1 Ω
Battery voltage is applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the relay.



Hide 85927B 3. FAN NO. 3 RELAY

a.
A167865E12
1.99,0.74 1.531,0.385 true 2.656,0.74 3.063,0.365 true 2.521,1.125 3.052,1.125 true 2.531,1.625 3.073,1.625 true 1.208,0.75 1.344,1 0.135,0.25 10 false 5 0.208,0.76 0.375,0.969 0.167,0.208 10 false 3 0.198,1.313 0.354,1.604 0.156,0.292 10 false 2 1.208,1.302 1.396,1.521 0.188,0.219 10 false 1 1.406,0.24 1.594,0.458 0.188,0.219 10 false 1 3.125,0.219 3.281,0.51 0.156,0.292 10 false 2 3.146,1.542 3.313,1.75 0.167,0.208 10 false 3 3.125,1.031 3.26,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the relay.