85927
1. FAN NO. 1 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.
85927A
2. FAN NO. 2 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage is not applied between terminals 1 and 2 | Below 1 Ω |
| Battery voltage is applied between terminals 1 and 2 | 10 kΩ or higher | |
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.
85927B
3. FAN NO. 3 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the relay.