28300
1.INSPECT ST RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Battery voltage not applied to terminals 1 and 2
Measurement temperature : 20 °C |
93.8 to 136.4 kΩ |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter relay.
2.REMOVE INHIBITOR RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Battery voltage not applied to terminals 1 and 2
Measurement temperature : 20 °C |
93.8 to 136.4 kΩ |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter relay.
3.INSPECT ST CUT RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Battery voltage not applied to terminals 1 and 2
Measurement temperature : 20 °C |
93.8 to 136.4 kΩ |
| 3 - 4 | Battery voltage not applied to terminals 1 and 2 | Below 1 Ω |
| Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher | |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter relay.
4.INSPECT IGS RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Battery voltage not applied to terminals 1 and 2
Measurement temperature : 20 °C |
93.8 to 136.4 kΩ |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter relay.