Home › Drivetrain › TX6A (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM
RM2090E _52 Drivetrain _060674 TX6A AUTOMATIC TRANSMISSION / TRANSAXLE _0297556 AUTOMATIC TRANSMISSION SYSTEM C

TX6A AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P1817  Manual Mode Switch Circuit Malfunction  


DESCRIPTION

A signal from the manual mode switch assembly input into the TCM detects the M position.

DTC Code DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P1817
1.

Shift position sensor is normal, and not in learning control prohibited status.

2.

The shift lever is in P, N, or R, and the M switch is on.

3.

Continues for 2 sec.

4.

1-trip detection logic


·

Manual mode switch

·

Harness and connector

·

TCM



WIRING DIAGRAM

C259257E04
5.792,3.01 6.104,3.198 0.313,0.188 10 false TCM 5.802,2.844 6.083,3.042 0.281,0.198 10 false A19 5.354,1.333 5.552,1.5 0.198,0.167 10 false 8 1.167,2.021 2.49,2.198 1.323,0.177 10 false Manual Mode Switch 3.292,2.01 4.125,2.385 0.833,0.375 10 false Shift Position Indicator 4.469,1.344 4.656,1.521 0.188,0.177 10 false 5 3.125,1.333 3.313,1.542 0.188,0.208 10 false 6 3.302,1.844 3.927,2.031 0.625,0.188 10 false D36 1.177,1.865 1.802,2.115 0.625,0.25 10 false D28 2.365,1.344 2.813,1.5 0.448,0.156 10 false 10 0.938,1.365 1.521,1.521 0.583,0.156 10 false 11 4.24,1.427 4.469,1.625 0.229,0.198 10 false M 3.333,1.427 3.625,1.646 0.292,0.219 10 false MM 1.969,1.344 2.771,1.521 0.802,0.177 10 false MM+ 1.208,1.354 2.063,1.635 0.854,0.281 10 false MM- 5.552,1.542 5.75,1.677 0.198,0.135 10 false M

PROCEDURE

1.CHECK MANUAL MODE SWITCH
a.

Disconnect the A19 TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Shift Position Specified Condition
A19-8(M) - Body ground M Below 1 Ω
A19-8(M) - Body ground Except M 10 kΩ or higher



c.

Connect the A19 TCM connector.



OK

2.REPLACE TCM

NG

3.CHECK HARNESS AND CONNECTOR (MANUAL MODE SWITCH - SHIFT POSITION INDICATOR)
3.CHECK HARNESS AND CONNECTOR (MANUAL MODE SWITCH - SHIFT POSITION INDICATOR)
a.

Disconnect the D36 shift position indicator connector.


b.

Disconnect the D28 manual mode switch connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D36-6(MM) - D28-10(MM+) Always Below 1 Ω
D36-6(MM) - Body ground Always 10 kΩ or higher
D28-10(MM+) - Body ground Always 10 kΩ or higher



d.

Connect the D36 shift position indicator connector.


e.

Connect the D28 manual mode switch connector.



OK

4.INSPECT MANUAL MODE SWITCH

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.INSPECT MANUAL MODE SWITCH
a.

Disconnect the D28 manual mode switch connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Shift Position Specified Condition
D28-10(MM+) - D28-11(MM-) M Below 1 Ω
Except M 10 kΩ or higher



c.

Disconnect the D28 manual mode switch connector.



OK

5.CHECK HARNESS AND CONNECTOR (TCM - SHIFT POSITION INDICATOR)

NG

5.CHECK HARNESS AND CONNECTOR (TCM - SHIFT POSITION INDICATOR)
a.

Disconnect the A19 TCM connector.


b.

Disconnect the D36 shift position indicator connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D36-5(M) - A19-8(M) Always Below 1 Ω
D36-5(M) - Body ground Always 10 kΩ or higher
A19-8(M) - Body ground Always 10 kΩ or higher



d.

Connect the A19 TCM connector.


e.

Connect the D36 shift position indicator connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR