1.INSPECT NEEDLE ROLLER BEARING
Install the input shaft to the output shaft, and then check the needle roller bearing.
Abnormal fitting, interfering, abnormal noise, or looseness should not be found.
If any abnormality is found, replace the needle roller bearing with a new one.
2.INSPECT RADIAL CLEARANCE
Install the input shaft to the output shaft, and then using a dial indicator, measure the radial clearance.
0.029 to 0.072 mm (0.00114 to 0.00283 in.)
0.072 mm (0.00283 in.)
If the clearance exceeds the maximum, replace the needle roller bearing and output shaft with a new ones.
3.INSPECT FRONT INPUT SHAFT BEARING
Check the front input shaft bearing.
Abnormal fitting, interfering, abnormal noise, or looseness should not be found.
If any abnormality is found, replace the front input shaft bearing with a new one.
4.REMOVE NEEDLE ROLLER BEARING
Remove the needle roller bearing from the input shaft.
5.REMOVE NO. 2 SYNCHRONIZER RING
Remove the No. 2 synchronizer ring from the input shaft.
6.REMOVE FRONT INPUT SHAFT BEARING
Using 2 screwdrivers and a hammer, remove the shaft snap ring from the input shaft.
Use a cloth to prevent the shaft snap ring from popping out.
Using SST and a press, remove the front input shaft bearing from the input shaft.