1.INSPECT BRUSH
Using a vernier caliper, measure the brush length.
22.5 mm (0.885 in)
5.0 mm (0.196 in)
| *a | Minimum length |
| *b | Standard length |
| *c | Mark of minimum length |
|
Brush |
If the brush length is less than the minimum, replace the brush.
27360
2.INSPECT GENERATOR COIL ASSEMBLY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Always | Below 1 Ω |
| 1 - 3 | ||
| 2 - 3 | ||
| 4 - 5 | ||
| 4 - 6 | ||
| 5 - 6 |
| *a | Lead wire |
If the result is not as specified, replace the generator coil assembly.
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Stator core - Lead wire | Always | 10 kΩ or higher |
| *1 | Stator core |
| *a | Lead wire |
If the result is not as specified, replace the generator coil assembly.
27330
3.INSPECT GENERATOR ROTOR ASSEMBLY
Check the generator rotor assembly for open circuits.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Slip ring | 20°C (68°F) | 2.0 to 2.4 Ω |
| *1 | Slip Ring |
If the result is not as specified, replace the generator rotor assembly.
Check if the generator rotor assembly is grounded.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Slip ring - Rotor core | Always | 10 kΩ or higher |
| *1 | Slip Ring |
| *2 | Rotor Core |
If the result is not as specified, replace the generator rotor assembly.
Check the slip ring diameter.
Using a vernier caliper, measure the diameter of each slip ring.
22.7 mm (0.893 in.)
22.1 mm (0.870 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
| *a | Diameter of Slip Ring |
27357
4.INSPECT GENERATOR HOLDER WITH RECTIFIER
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| P1, P2, P3, P4, P5, P6 - B | P1, P2, P3, P4, P5, P6 (Tester positive)
B (Tester negative) |
Below 1 Ω |
| P1, P2, P3, P4, P5, P6 (Tester negative)
B (Tester positive) |
10 kΩ or higher | |
| P1, P2, P3, P4, P5, P6 - E | P1, P2, P3, P4, P5, P6 (Tester positive)
E (Tester negative) |
10 kΩ or higher |
| P1, P2, P3, P4, P5, P6 (Tester negative)
E (Tester positive) |
Below 1 Ω |
If the result is not as specified, replace the generator holder with rectifier.