Home › Power Source / Network › FA20 (BATTERY / CHARGING) › GENERATOR
RM2090E _57 Power Source / Network _060693 FA20 BATTERY / CHARGING _0297660 GENERATOR G

FA20 BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT BRUSH

a.
A277222E02
1.323,0.354 1.49,0.531 0.167,0.177 10 false *a 0.854,0.521 1.021,0.698 0.167,0.177 10 false *c 1.031,1 1.198,1.177 0.167,0.177 10 false *b

Using a vernier caliper, measure the brush length.

Standard length:

22.5 mm (0.885 in)


Minimum length:

5.0 mm (0.196 in)


Text in Illustration
*a Minimum length
*b Standard length
*c Mark of minimum length
V100145

Brush

If the brush length is less than the minimum, replace the brush.


Hide 27360 2.INSPECT GENERATOR COIL ASSEMBLY

a.
A398291E01
0.792,0.375 1.479,0.917 true 0.594,0.219 0.906,0.417 0.313,0.198 10 false *a 1.49,1 1.802,1.198 0.313,0.198 10 false 1 1.677,0.896 1.99,1.094 0.313,0.198 10 false 2 1.906,0.521 2.219,0.719 0.313,0.198 10 false 3 2.344,0.729 2.656,0.927 0.313,0.198 10 false 4 2.49,1.021 2.802,1.219 0.313,0.198 10 false 5 2.552,1.344 2.865,1.542 0.313,0.198 10 false 6

Check the resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 Always Below 1 Ω
1 - 3
2 - 3
4 - 5
4 - 6
5 - 6


Text in Illustration
*a Lead wire

If the result is not as specified, replace the generator coil assembly.



b.
A277223E02
0.552,1.76 1.052,1.656 false 1.49,0.802 1.875,0.823 true 1.292,0.719 1.469,0.885 0.177,0.167 10 false *a 0.354,1.688 0.531,1.854 0.177,0.167 10 false *1

Check the resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Stator core - Lead wire Always 10 kΩ or higher


Text in Illustration
*1 Stator core
*a Lead wire

If the result is not as specified, replace the generator coil assembly.



Hide 27330 3.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A277225E03
2.104,0.781 2.521,0.313 2.521,0.313 2.271,0.781 true 2.51,0.167 2.698,0.344 0.188,0.177 10 false *1

Check the generator rotor assembly for open circuits.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 2.0 to 2.4 Ω


Text in Illustration
*1 Slip Ring

If the result is not as specified, replace the generator rotor assembly.



b.
A277226E03
2.115,0.823 2.625,0.427 false 1.115,1.833 1.167,1.5 true 2.656,0.292 2.833,0.479 0.177,0.188 10 false *1 1.042,1.875 1.219,2.063 0.177,0.188 10 false *2

Check if the generator rotor assembly is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 kΩ or higher


Text in Illustration
*1 Slip Ring
*2 Rotor Core

If the result is not as specified, replace the generator rotor assembly.



c.

Check the slip ring diameter.

i.
A182587E05
0.563,0.615 0.719,0.792 0.156,0.177 10 false *a

Using a vernier caliper, measure the diameter of each slip ring.

Standard diameter:

22.7 mm (0.893 in.)


Minimum diameter:

22.1 mm (0.870 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.

Text in Illustration
*a Diameter of Slip Ring



Hide 27357 4.INSPECT GENERATOR HOLDER WITH RECTIFIER

a.
A277227E02
0.552,1.552 0.854,1.365 false 1.385,1.615 1.708,1.688 false 0.385,1.104 1.042,0.802 true 0.406,0.74 1.042,0.688 true 0.521,0.365 1.156,0.51 true 0.854,0.146 1.552,0.323 true 1.885,0.313 2.573,0.115 true 2.219,0.365 2.958,0.385 true 0.396,1.531 0.531,1.698 0.135,0.167 10 false E 1.771,1.625 1.906,1.792 0.135,0.167 10 false B 0.177,1.042 0.396,1.208 0.219,0.167 10 false P1 0.177,0.667 0.396,0.833 0.219,0.167 10 false P2 0.302,0.271 0.521,0.438 0.219,0.167 10 false P3 0.625,0.052 0.844,0.219 0.219,0.167 10 false P4 2.635,0.052 2.854,0.219 0.219,0.167 10 false P5 3.031,0.302 3.25,0.469 0.219,0.167 10 false P6

Check the resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
P1, P2, P3, P4, P5, P6 - B P1, P2, P3, P4, P5, P6 (Tester positive)
B (Tester negative)
Below 1 Ω
P1, P2, P3, P4, P5, P6 (Tester negative)
B (Tester positive)
10 kΩ or higher
P1, P2, P3, P4, P5, P6 - E P1, P2, P3, P4, P5, P6 (Tester positive)
E (Tester negative)
10 kΩ or higher
P1, P2, P3, P4, P5, P6 (Tester negative)
E (Tester positive)
Below 1 Ω


If the result is not as specified, replace the generator holder with rectifier.