This circuit is the power source circuit for the combination meter assembly.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the D7 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D7-1 (B) - Body ground | Always | 11 to 14 V |
| D7-2 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
Measure the resistance according to the value in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D7-20 (ES1) - Body ground | Always | Below 1 Ω |
| D7-40 (ES2) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Reconnect the D7 combination meter assembly connector.
OK
NG