The thermistor assembly is installed in the front part of the cooler condenser assembly to display the ambient temperature on the multi-information display in the combination meter assembly and to control the air conditioning auto mode. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies a voltage (5 V) to the thermistor assembly and reads the voltage changes as changes in the resistance of the thermistor assembly.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1509 | An open or short in the thermistor assembly circuit. | ·
Thermistor assembly ·
Harness or connector ·
Combination meter assembly |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temperature | Thermistor assembly /
Min: -40.0°C (-40.0°F) Max: 87.5°C (189.5°F) |
Actual ambient temperature displayed | Open in the circuit: -40.0°C (-40.0°F)
Short in the circuit: 87.5°C (189.5°F) |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to problem symptoms table) | B |
| NG | C |
A
B
C
Clear the DTCs (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DTC CHECK / CLEAR).
Check for DTCs (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DTC CHECK / CLEAR).
DTC B1509 is not output
OK
NG
Remove the thermistor assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL).
Inspect the thermistor assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>INSPECTION).
OK
NG
Disconnect the A48 thermistor assembly connector.
Disconnect the D7 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A48-1 - D7-24 (TAM) | Always | Below 1 Ω |
| A48-2 - D7-25 (SG-) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A48-1 - Body ground | Always | 10 kΩ or higher |
| A48-2 - Body ground | Always | 10 kΩ or higher |
OK
NG