Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM2090E _58 Vehicle Interior _060704 HEATING / AIR CONDITIONING _0297734 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  IG Power Source Circuit  


DESCRIPTION

The main power source is supplied to the air conditioning control assembly when the ignition switch is ON.

The power is used for operating the air conditioning control assembly, servo motors, etc.

WIRING DIAGRAM

E229257E78
5.885,2.219 6.208,2.385 0.323,0.167 10 false GND 5.656,0.854 5.833,1.01 0.177,0.156 10 false 10 5.656,2.125 5.823,2.281 0.167,0.156 10 false 16 5.469,3.583 5.75,3.75 0.281,0.167 10 false D19 5.469,3.76 6.906,4.115 1.438,0.354 10 false Air Conditioning Control Assembly 0.24,1.604 1.594,1.948 1.354,0.344 10 false from Ignition Switch*1 or Certification ECU*2 0.854,3.646 2.792,3.833 1.938,0.188 10 false *1: w/o Entry and Start System 0.854,4 2.698,4.208 1.844,0.208 10 false *2: w/ Entry and Start System 5.906,0.958 6.125,1.135 0.219,0.177 10 false IG 4.479,1.198 5.083,1.375 0.604,0.177 10 false HEATER 2.854,1.917 3.896,2.094 1.042,0.177 10 false IG1 NO. 3 Relay 0.802,0.938 1.573,1.115 0.771,0.177 10 false from Battery

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY)
a.

Disconnect the D19 air conditioning control assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
D19-10(IG) - Body ground Ignition switch off Below 1 V
D19-10(IG) - Body ground Ignition switch ON 11 to 14 V




OK

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND)
a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D19-16(GND) - Body ground Always Below 1 Ω




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR